1. Scope description

1.1 Introduction

The Schmidt & Bender Zenith hunting scopes are designed to meet the unique challenges of high precision shooting. Their quality and function make it possible to achieve exceptional shooting results as well as to fulfill the critical and demanding needs of official, law enforcement and tactical applications. Strict observation of the following operating instructions is prerequisite for successful long-term use.

1.2 Safety instructions

Never look into the sun or into laser light with the scope. This may cause serious eye injuries. Do not tamper with the scope. Any repairs beyond the
maintenance described in the maintenance manual should only be
performed by Schmidt & Bender or by other specialists authorized by Schmidt & Bender. Protect the scope against shocks beyond normal use.

Avoid unnecessary long exposure of the scope to direct sunlight; intense and excessive sun radiation will cause extremely high temperatures inside the tube which may be detrimental to the scope.

The scope must be properly mounted to the firearm by a qualified specialist.
Perfect mounting is an essential requirement for maximum accuracy and
efficient functioning of the firearm and the scope. Be sure to assume the
proper firing position and keep a correct eye relief in order to obtain an
optimal full field of view and to avoid any injuries due to the recoil of the
weapon.

2. Technical data

2.1 General data

Field of view
Exit pupil
Eye relief
Twilight factor
Transmission
Diopter adjustment
Parallax
Reticle focal plane
36,0 – 9,2 (m/100m)
14,1 – 5,9 (mm)
90 (mm)
5,1 – 9,8
90 (%)
+2 to -3 (dpt)
fix 100 (m)
2nd

2.2 Dimensions

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

3. Accessories / Scope of supply

The following accessories are supplied along with the riflescope. These parts
can be ordered from a specialist dealer or our service if necessary.
Further accessories can be found on our homepage.

Protective Caps
Registration card
Reply card

4. Operating instructions

Your new Schmidt & Bender riflescope consists of different functional parts
and adjustments (See Illustr. 2).

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

4.1 Adjusting the image focus with the diopter adjustment of the eyepiece

The eyepiece provides the adjustment of the reticle focus to the individual
eye diopter. Set the scope to the highest magnification. Rotate the eyepiece
counterclockwise until it stops. Rotate the eyepiece clockwise until you see a
sharp image of the reticle (see Illustr. 3).

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

4.2 Illumination control

Your new riflescope is equipped with the Flash Dot technology which provides a projected bright red dot along with a reticle in the second focal plane.

The bright red dot positioned in the center of the reticle vanishes completely when switched off.

For optimal target acquisition on dark background, set the intensity of the
illuminated dot to the respective light conditions.

To do this the illumination control may be turned from -0- toward position -11- until a setting is achieved where the red dot is just bright enough to be picked up by the eye without glaring. If possible, this adjustment should be performed under quiet conditions prior to the actual shooting (see Illustr. 4).

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

If the illumination is not switched off by the shooter after use, illumination
control electronics automatically switch off the illumination after 6 hours.

If the illumination starts blinking, the battery is low and should be replaced.

4.3 Changing the battery

To replace the battery screw off the battery cap and remove the old battery.

Please discard the used battery in an ecologically compatible way!
Place the new battery (coin cell CR 2032/3V) with the „+” facing up into the
battery compartment. Do only change the battery in a dry environment.
Battery service life is at least 100 hours at the highest intensity (see Illustr. 5).

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

5. Preliminary adjusting and fine adjusting when sighting in

5.1 Using the Posicon turrets

For use of the turrets, please remove the caps from the windage and
elevation turret by unscrewing counter-clockwise (Illustr. 6).

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

Your new riflescope is equipped with the Posicon-windage and elevation
adjustment. On delivery, the black arrow in the white screen of the turret
indicator points onto the center, symbolized by an – o -.

This ensures that in both left-to-right and up-to-down direction the maximal
amount of adjustment range is available.

The arrow of the so called “Posicon-Clock” provides information on the
position of the reticle at any time (Illustr. 7).

The green sector indicates the square adjustment range in which one
windage and elevation adjustment do not interfere with each other. The red
sector indicates the so called buffer, which provides an additional amount of
adjustment in either direction, but in which one adjustment direction might
interfere with the other.

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

When sighting in the scope for the first time, or re-sighting the scope due to
service or repair, a test shoot for zeroing the scope must be performed on a
100m distance.

The centering of the target pattern and thus zeroing of the scope is then
performed according to paragraph 5.2 and 5.3.

5.2 Elevation adjustment

The point of impact is moved by 1,5cm on 100 m on every click. A too low
point of impact is corrected by rotating the elevation turret clockwise into the direction indicated by “H” or “U”, (see Illustr. 8), a too high point of impact by rotating the elevation turret counter-clockwise into the direction indicated by “T” or “D”.

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

5.3 Windage adjustment

The point of impact is moved by 1,5cm on 100m on every click. A too far left
point of impact is corrected by rotating the elevation turret clockwise into the direction indicated by “R”, (see Illustr. 9), a too high point of impact by
rotating the elevation turret counter-clockwise into the direction indicated by “L”.

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

5.4 Marking the zero position

All obtained reticle positions may be marked by the aluminum ring below the knurl.

To do so, please unscrew the cross-slot screw in the Posicon screen and
position and turn the aluminum ring until the index dot and the index triangle match. Then screw the cross-slot screw tightly (Illustr. 10).

Instructions SCHMIDT & BENDER 1.1-4x24 Zenith
Instructions SCHMIDT & BENDER 1.1-4×24 Zenith

6. Maintenance

6.1 Care and Maintanance

Schmidt & Bender Zenith line scopes do not require any special maintenance. All metal parts have a hard anodized surface that is extremely scratchresistant and easy to care for.

For cleaning outer surfaces, use a clean and, if necessary, a slightly damp
cloth.

Before wiping the optic’s surfaces, use a dry brush to remove coarse dirt or
dust particles. Slight impurities may then be wiped off using a microfibre cloth.

Breathe onto the optic’s surfaces before cleaning them, this helps with the
cleaning process. Excessive dirt may be removed using lukewarm water.
Avoid dry rubbing on the outside optical surfaces, this may harm the precious coatings.

6.2 Storage temperature

The approved temperature range for the storage of the scope is from -55°C
to 70°C.

7. Warranty certificate

We hereby certify that our Quality Management System has been approved
by Unternehmensgruppe TUV Rheinland Berlin Brandenburg to the following Quality Management Standard: The TUV Cert Certification Body of TUV Anlagentechnik GmbH (Unternehmensgruppe TUV Rheinland Berlin
Brandenburg) certifies in accordance with TUV Cert procedures that Schmidt
& Bender GmbH & Co. KG, Am Grossacker 42, D- 35444 Biebertal has
established and applies a quality management system for the design,
production sales and service of fine mechanical optical instruments. Main
product telescopic sights. Proof has been furnished that the requirements
according to ISO 9001 – # Registration No. 01 100 67280 – are fulfilled. All parts have been thoroughly inspected in accordance with the afore-mentioned Quality Management System and correspond to the requirements of the specifications, drawings, test procedures and standards in all respects.

Guarantee clause:
– Guarantee period of 10 years
– Replacement parts are available for at least 30 years

Contact:
Schmidt & Bender GmbH & Co. KG • Am Grossacker 42 • D-35444 Biebertal • Germany
Tel. +49 (0) 64 09-81 15-0 • Fax +49 (0) 64 09-81 15-11
[email protected] • www.schmidt-bender.de

Schmidt & Bender Inc. • 204 McGhee Rd• Winchester, VA 22603• U.S.A.
• Phone +1(540)4508132• [email protected]

SHARE THIS POST

YOU MIGHT ALSO LIKE

Leave a Reply

Your email address will not be published. Required fields are marked *