{"id":5708980,"date":"2026-04-29T09:30:52","date_gmt":"2026-04-29T07:30:52","guid":{"rendered":"https:\/\/www.optics-trade.eu\/blog\/?p=5708980"},"modified":"2026-05-29T11:52:43","modified_gmt":"2026-05-29T09:52:43","slug":"pulsar-symbion-instruction-manual","status":"publish","type":"post","link":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/","title":{"rendered":"Pulsar Symbion Instruction Manual"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"602\" height=\"400\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png\" alt=\"\" class=\"wp-image-5710068\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png 602w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859-400x266.png 400w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859-600x400.png 600w\" sizes=\"auto, (max-width: 602px) 100vw, 602px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li><strong><a href=\"https:\/\/www.lovskatrgovina.si\/slo\/pulsar-symbion-lrf-dxt50.html\" target=\"_blank\" rel=\"noreferrer noopener\">Pulsar Symbion LRF DXT50<\/a><\/strong><\/li>\n\n\n\n<li><strong><a href=\"https:\/\/www.lovskatrgovina.si\/slo\/pulsar-symbion-lrf-dxr50.html\" target=\"_blank\" rel=\"noreferrer noopener\">Pulsar Symbion LRF DXR50<\/a><\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Specification<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Model<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>DXT50<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">SKU<\/td><td class=\"has-text-align-center\" data-align=\"center\">77456<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Microbolometer<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Type<\/td><td class=\"has-text-align-center\" data-align=\"center\">uncooled<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Resolution, pixels<\/td><td class=\"has-text-align-center\" data-align=\"center\">1280\u00d71024<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Pixel Pitch, \u00b5m<\/td><td class=\"has-text-align-center\" data-align=\"center\">12<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Sensor NETD, mK<\/td><td class=\"has-text-align-center\" data-align=\"center\">&lt; 40<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">System NETD, mK<\/td><td class=\"has-text-align-center\" data-align=\"center\">&lt; 20<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Frame rate, Hz<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Digital Sensor<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Type<\/td><td class=\"has-text-align-center\" data-align=\"center\">CMOS<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Resolution, pixels<\/td><td class=\"has-text-align-center\" data-align=\"center\">3840\u00d72160<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Optical Characteristics<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Thermal imaging channel:<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Lens<\/td><td class=\"has-text-align-center\" data-align=\"center\">50 mm F\/1.0<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Magnification, x<\/td><td class=\"has-text-align-center\" data-align=\"center\">2 \u2013 16<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Field of view angle (horizontal), \u00b0\/m@100<\/td><td class=\"has-text-align-center\" data-align=\"center\">17.5 \/ 30.7<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Detection distance (deer-type object), m<\/td><td class=\"has-text-align-center\" data-align=\"center\">2300<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Digital channel:<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Focal length<\/td><td class=\"has-text-align-center\" data-align=\"center\">50 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Magnification, x<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.5 \u2013 26<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Digital zoom<\/td><td class=\"has-text-align-center\" data-align=\"center\">x1, x2, x4<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Field of view angle (horizontal), \u00b0\/m@100<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.8 \/ 10.2<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Minimum Focus Distance, m\/yd<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 \/ 3.28<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Eye relief, mm\/inch<\/td><td class=\"has-text-align-center\" data-align=\"center\">13 \/ 0.51<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Exit pupil diameter, mm\/inch<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 \/ 0.2<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Diopter adjustment, D<\/td><td class=\"has-text-align-center\" data-align=\"center\">-5\/+5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Interpupillary distance adjustment, mm \/ inch<\/td><td class=\"has-text-align-center\" data-align=\"center\">62.5 \u2013 74 \/ 2.46 \u2013 2.91<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Display<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Type<\/td><td class=\"has-text-align-center\" data-align=\"center\">AMOLED<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Resolution, pixels<\/td><td class=\"has-text-align-center\" data-align=\"center\">1920\u00d71080<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Operational Characteristics<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power supply, V<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.7<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Battery type \/ Capacity \/ Output voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">Li-Ion Battery Pack APS 5 \/ 4900 mAh<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">External power supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 V, 9 V (USB Type-C Power Delivery)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Operating time from 2 APS 5 battery packs at t=22 \u00b0C, hours*<\/td><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Degree of protection, IP code (IEC60529)<\/td><td class=\"has-text-align-center\" data-align=\"center\">IP67<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Operating temperature range, \u00b0\u0421 \/\u00b0 F<\/td><td class=\"has-text-align-center\" data-align=\"center\">-25 \u2026 +40 \/ -13 \u2026 104<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Dimensions, mm \/ inch<\/td><td class=\"has-text-align-center\" data-align=\"center\">207x132x72.5 \/ 8.2\u00d75.2\u00d72.9<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Weight (with battery), kg \/ oz<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 \/ 35.3<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Video Recorder<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Video \/ photo resolution, pixel<\/td><td class=\"has-text-align-center\" data-align=\"center\">1440\u00d71080<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Video \/ photo format<\/td><td class=\"has-text-align-center\" data-align=\"center\">.mp4 \/ .jpg<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Built-in memory<\/td><td class=\"has-text-align-center\" data-align=\"center\">64 Gb<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Wi-Fi Channel**<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Frequency<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.4\/5 GHz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Standard<\/td><td class=\"has-text-align-center\" data-align=\"center\">IEEE 802.11 b\/g\/n\/ac<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Bluetooth<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Wireless Protocol<\/td><td class=\"has-text-align-center\" data-align=\"center\">BLE 4.2<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Laser rangefinder<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Wavelength, nm<\/td><td class=\"has-text-align-center\" data-align=\"center\">905<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Max. measuring range, m\/yd***<\/td><td class=\"has-text-align-center\" data-align=\"center\">1500\/1640<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IR-Illuminator<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Type<\/td><td class=\"has-text-align-center\" data-align=\"center\">LED<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Wavelength, nm<\/td><td class=\"has-text-align-center\" data-align=\"center\">850<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Actual operating time depends on the degree of use of Wi-Fi, video recorder, built-in laser rangefinder, Bluetooth, IR illuminator, active observation channels and activated power saving mode.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">**The reception range may vary depending on various factors: obstacles, other Wi-Fi networks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">***Depends on the characteristics of the object under observation and environmental conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">About the device<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Symbion LRF multispectral binoculars are high-tech devices designed for various applications, such as hunting, search and rescue operations, nature conservation, wildlife observation, and active tourism. ymbion LRF binoculars allow you to quickly switch between thermal imaging and digital channels. The digital hannel can be used in both color and black-and-white modes. There is support for the Duo ltispectral mode, where the image from one channel is displayed in the main window and the image from the second channel is displayed in a PiP (Picture in Picture) window. The thermal imaging channel can be used both at night and during the day, including in difficult weather conditions (fog, smog, rain) and in the presence of obstacles hat make it difficult to detect targets (branches, tall grass, thick bushes, etc.). In digital mode, the device allows  for observation both during the day and at night. In night conditions, it is recommended to use a focusable infrared illuminator. To get started, see the sections:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Battery Charging<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Battery Installation<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Getting Started<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Using the Laser Rangefinder<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Stream Visiun 2<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Package Contents<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Symbion LRF multispectral binoculars<\/li>\n\n\n\n<li>APS 5 rechargeable battery (2 pcs.)<\/li>\n\n\n\n<li>APS 5 battery caps (2 pcs.)<\/li>\n\n\n\n<li>APS 5 charger<\/li>\n\n\n\n<li>Power adapter<\/li>\n\n\n\n<li>USB Type-C cable with Type-A adapter<\/li>\n\n\n\n<li>Carrying case for binoculars<\/li>\n\n\n\n<li>Binoculars harness<\/li>\n\n\n\n<li>Neck strap<\/li>\n\n\n\n<li>Optics cleaning cloth<\/li>\n\n\n\n<li>Quick start guide<\/li>\n\n\n\n<li>Warranty card<\/li>\n\n\n\n<li>Tripod adapter<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Components and Controls<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"424\" height=\"375\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-1-1.png\" alt=\"\" class=\"wp-image-5709129\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-1-1.png 424w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-1-1-400x354.png 400w\" sizes=\"auto, (max-width: 424px) 100vw, 424px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"411\" height=\"395\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-2-1.png\" alt=\"\" class=\"wp-image-5709130\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-2-1.png 411w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-2-1-400x384.png 400w\" sizes=\"auto, (max-width: 411px) 100vw, 411px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"418\" height=\"265\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-3-1.png\" alt=\"\" class=\"wp-image-5709131\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-3-1.png 418w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-3-1-400x254.png 400w\" sizes=\"auto, (max-width: 418px) 100vw, 418px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"431\" height=\"348\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-4-1.png\" alt=\"\" class=\"wp-image-5709132\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-4-1.png 431w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-4-1-400x323.png 400w\" sizes=\"auto, (max-width: 431px) 100vw, 431px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Thermal channel focusing ring<\/li>\n\n\n\n<li>Digital channel focusing ring<\/li>\n\n\n\n<li>Battery compartment<\/li>\n\n\n\n<li>IR-illuminator<\/li>\n\n\n\n<li>Thermal channel lens<\/li>\n\n\n\n<li>Digital channel lens<\/li>\n\n\n\n<li>Laser rangefinder<\/li>\n\n\n\n<li>Diopter adjustment rings<\/li>\n\n\n\n<li>Eyepieces<\/li>\n\n\n\n<li>USB-C port<\/li>\n\n\n\n<li>ON\/Sleep\/OFF switch<\/li>\n\n\n\n<li>Tripod adapter socket<\/li>\n\n\n\n<li>Lens caps<\/li>\n\n\n\n<li>Microphone<\/li>\n\n\n\n<li>Proximity sensor<\/li>\n\n\n\n<li>IR focusing switch<\/li>\n\n\n\n<li>REC button<\/li>\n\n\n\n<li>BACK button<\/li>\n\n\n\n<li>Calibration\/Stabilization button<\/li>\n\n\n\n<li>DUO button<\/li>\n\n\n\n<li>MODE button<\/li>\n\n\n\n<li>LRF button<\/li>\n\n\n\n<li>MENU button<\/li>\n\n\n\n<li>Controller ring<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Multispectral image \u2013 digital and thermal<\/li>\n\n\n\n<li>24\/7 use \u2013 day, night, twilight<\/li>\n\n\n\n<li>Combined multispectral Picture-in-Picture modes<\/li>\n\n\n\n<li>4K Digital full-color sensor<\/li>\n\n\n\n<li>HD 1280\u00d71024\/12\u00b5m premium thermal imaging sensor (For XT50 model)<\/li>\n\n\n\n<li>Built-in powerful laser rangefinder<\/li>\n\n\n\n<li>Focusable infrared illuminator<\/li>\n\n\n\n<li>Optimized for one-hand use<\/li>\n\n\n\n<li>Left-hand mode<\/li>\n\n\n\n<li>New user-friendly graphic interface<\/li>\n\n\n\n<li>Classic daytime binocular design<\/li>\n\n\n\n<li>9-color display palette<\/li>\n\n\n\n<li>3 calibration modes: manual, semi-automatic and automatic<\/li>\n\n\n\n<li>Long detection distance<\/li>\n\n\n\n<li>Smooth digital zoom<\/li>\n\n\n\n<li>3 levels of sensitivity enhancement: Normal, High, Ultra<\/li>\n\n\n\n<li>Auto Display-Off Using Proximity Sensor<\/li>\n\n\n\n<li>Display dimming function<\/li>\n\n\n\n<li>Auto shutdown function<\/li>\n\n\n\n<li>Image stabilization<\/li>\n\n\n\n<li>Defective Pixel Repair function<\/li>\n\n\n\n<li>Device firmware update using the free Stream Vision 2 App<\/li>\n\n\n\n<li>Wide operating temperature range -25 \u00b0\u0421 \u2013 +40\u00b0\u0421 (-13 \u00b0F \u2026 104 \u00b0F)<\/li>\n\n\n\n<li>Completely waterproof and dustproof IP67<\/li>\n\n\n\n<li>Ballistic calculator<\/li>\n\n\n\n<li>2 display shapes<\/li>\n\n\n\n<li>Tripod mount<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Video\/Audio Recording<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Built-in video and sound recorder<\/li>\n\n\n\n<li>Integration with iOS and Android devices<\/li>\n\n\n\n<li>Wi-Fi remote control and viewing using a smartphone<\/li>\n\n\n\n<li>Storing photos and videos in Cloud when using the Stream Vision 2 App<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Battery Pack<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Quick Change Li-Ion Battery Pack APS 5<\/li>\n\n\n\n<li>Charging from USB Power Bank<\/li>\n\n\n\n<li>Quick-Charge power delivery<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Power Supply<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Precautions<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Only use the charger supplied with the Battery Pack. The use of any other charger may irreparably damage the Battery Pack or the charger and may cause fire.<\/li>\n\n\n\n<li>Do not charge batteries immediately after moving the device and batteries from a cold place to a warm place. Wait at least 30 minutes for the device and batteries to warm up.<\/li>\n\n\n\n<li>Do not leave the Battery Pack unattended while charging.<\/li>\n\n\n\n<li>Never use a modified or damaged charger.<\/li>\n\n\n\n<li>Do not leave the Battery Pack with a charger connected to the power adapter after charging is complete.<\/li>\n\n\n\n<li>Do not expose batteries to high temperatures or to a naked flame.<\/li>\n\n\n\n<li>Do not use batteries as a power source for devices that do not support APS batteries.<\/li>\n\n\n\n<li>Do not disassemble or bend batteries or charger.<\/li>\n\n\n\n<li>Do not drop or strike batteries or charger.<\/li>\n\n\n\n<li>Batteries and charger are not designed to be immersed in water.<\/li>\n\n\n\n<li>Keep the Battery Pack out of the reach of children<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Recommendations for Battery Use<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>For long-term storage, batteries should be partially charged \u2013 from 50 to 80%.<\/li>\n\n\n\n<li>Batteries should be charged at an ambient temperature of 0 \u00b0C \u2026 +35 \u00b0C (32 \u00b0F \u2026 95 \u00b0F). Otherwise, battery life will be significantly reduced.<\/li>\n\n\n\n<li>When using batteries at sub-zero (sub 32\u00b0 F) ambient temperatures, the battery capacity decreases, this is normal and not a defect.<\/li>\n\n\n\n<li>Do not use batteries at temperatures outside the range of -25 \u00b0C \u2026 +40 \u00b0C (-13 \u00b0F \u2026 104 \u00b0F) \u2013 it may reduce the battery life.<\/li>\n\n\n\n<li>The battery has a short-circuit protection. Any situation that may cause shortcircuiting, however, should be avoided.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Battery Charging<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Symbion LRF<\/strong> binoculars are supplied with a removable and rechargeable APS5 lithiumion battery pack. The battery should be charged before first use. The icon <img loading=\"lazy\" decoding=\"async\" width=\"71\" height=\"49\" class=\"wp-image-5709136\" style=\"width: 71px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-5-1.png\" alt=\"\">in the status bar will flash when the battery is low. The battery needs to be charged<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Option 1<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"402\" height=\"322\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-6-1.png\" alt=\"\" class=\"wp-image-5709137\" style=\"width:424px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-6-1.png 402w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-6-1-400x320.png 400w\" sizes=\"auto, (max-width: 402px) 100vw, 402px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Install<\/strong> the APS5 battery in the battery compartment of the device.<\/li>\n\n\n\n<li>Connect the USB Type-C cable <strong>(1)<\/strong> to the USB Type-C connector<strong> (2)<\/strong> of the device.<\/li>\n\n\n\n<li>Connect the other end of the USB cable <strong>(1) <\/strong>to the Power Adapter<strong> (3)<\/strong> by removing the USB Type-A adapter <strong>(4)<\/strong>.<\/li>\n\n\n\n<li>Plug the Power Adapter <strong>(3)<\/strong> into a 100-240 V socket.<\/li>\n\n\n\n<li>Wait until the battery is fully charged (indication in the status bar:<img loading=\"lazy\" decoding=\"async\" width=\"66\" height=\"36\" class=\"wp-image-5709138\" style=\"width: 66px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-8-1.png\" alt=\"\"> ).<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note: <\/strong>next to the USB Type-C connector on the device body there is a light-emitting <strong>(5)<\/strong> diode to indicate the battery charge level when the device is switched off.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>LED indication<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Battery status<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"36\" height=\"31\" class=\"wp-image-5709139\" style=\"width: 36px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-148.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery is charging<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"26\" height=\"24\" class=\"wp-image-5709140\" style=\"width: 26px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-149.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery is fully charged<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"22\" height=\"24\" class=\"wp-image-5709141\" style=\"width: 22px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-150.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery is defective.<strong> Do not use the battery!<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"405\" height=\"348\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-7-1.png\" alt=\"\" class=\"wp-image-5709143\" style=\"width:431px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-7-1.png 405w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-7-1-400x344.png 400w\" sizes=\"auto, (max-width: 405px) 100vw, 405px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Insert the APS 5 battery<strong> (1) <\/strong>along the guide into the APS 5 charger <strong>(2) <\/strong>slot as far as it will go. The APS 5 charger is supplied with your device or purchased separately.<\/li>\n\n\n\n<li>Connect the other end of the USB Type-C cable <strong>(3)<\/strong> to the Power Adapter<strong> (4) <\/strong>by removing the USB Type-A adapter.<\/li>\n\n\n\n<li>Plug the Power Adapter <strong>(4)<\/strong> into a 100-240 V socket.<\/li>\n\n\n\n<li>Connect the other end of the USB Type-C cable <strong>(3)<\/strong> to the USB Type-C connector<br><strong>(5)<\/strong> of the charger by removing the USB Type-A adapter <strong>(6)<\/strong>.<\/li>\n\n\n\n<li>LED indicators <strong>(7) <\/strong>will display the battery charge level (see Table).<\/li>\n\n\n\n<li>Wait until the battery is fully charged (LED indication:<img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\">)<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Note: Two batteries can be charged at the same time, a second slot is provided for it.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>indication in the battery<br>charging mode<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Battery Level<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"35\" class=\"wp-image-5709146\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-10-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 0% to 25%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"35\" class=\"wp-image-5709146\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-10-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 26% to 50%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"35\" class=\"wp-image-5709146\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-10-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 51% to 80%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"><img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"35\" class=\"wp-image-5709146\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-10-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 81% to 99%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery is fully charged. Charging will automatically stop. The battery can be disconnected from the charger.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"22\" height=\"24\" class=\"wp-image-5709147\" style=\"width: 22px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-150-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Defective battery. <strong>Do not use the battery!<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>LED indication in the standby<br>mode*<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Battery Level<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"35\" class=\"wp-image-5709146\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-10-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 0% to 25%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 26% to 50%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 51% to 80%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"><img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"> <img loading=\"lazy\" decoding=\"async\" width=\"27\" height=\"29\" class=\"wp-image-5709145\" style=\"width: 27px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-9-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Battery charge level is from 81% to 99%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"22\" height=\"24\" class=\"wp-image-5709147\" style=\"width: 22px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-150-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Defective battery.<strong> Do not use the battery!<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Standby mode is when the batteries are in the charger but the Power Adapter is not connected. In this   mode, the indicators are only on for 10 seconds.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Attention! <\/strong>When using a Power Adapter that does not support USB Power Delivery fast charging technology, the flicker frequency of the LED indicators decreases by a factor of 3 and the charge time increases.<br><strong>Attention!<\/strong> The charger heats up during fast charging. Excess heat is removed through the radiator and does not affect the device operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Battery Installation<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"419\" height=\"274\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-11-1.png\" alt=\"\" class=\"wp-image-5709148\" style=\"width:450px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-11-1.png 419w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-11-1-400x262.png 400w\" sizes=\"auto, (max-width: 419px) 100vw, 419px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Place the battery compartment cover <strong>(1) <\/strong>on the<strong> (2)<\/strong>.<\/li>\n\n\n\n<li>Insert the battery<strong> (2)<\/strong> into the battery compartment <strong>(3) <\/strong>along the guides until it is fully seated.<\/li>\n\n\n\n<li>Turn the cover so that the handle<strong> (4)<\/strong> aligns with the recess on the body.<\/li>\n\n\n\n<li>Close the battery compartment cover handle <strong>(4)<\/strong><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Removing the Battery<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Pull the battery compartment cover handle <strong>(3)<\/strong>.<\/li>\n\n\n\n<li>Turn the cover<strong> (1) <\/strong>counterclockwise until it stops.<\/li>\n\n\n\n<li>Pull the handle <strong>(3)<\/strong> toward you and carefully remove the battery <strong>(2)<\/strong> from the compartment <strong>(3).<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Precautions:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Do not rotate the cover <strong>(1) <\/strong>relative to the battery <strong>(2)<\/strong> once it is attached.<\/li>\n\n\n\n<li>When removing the cover <strong>(1)<\/strong>, slide it horizontally relative to the battery <strong>(2). <\/strong>Do not lift it upward during removal.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"384\" height=\"303\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-12-1.png\" alt=\"\" class=\"wp-image-5709149\" style=\"width:414px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">External Power Supply<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Power can be supplied from an external source such as a 5 V or 9 V power bank.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Connect the external power supply to the USB Type-C port of the device.<\/p>\n\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li>The device switches to external power source, while the removable Battery Pack APS5 will gradually recharge.<\/li>\n\n\n\n<li>The display will show the battery icon <img loading=\"lazy\" decoding=\"async\" width=\"77\" height=\"53\" class=\"wp-image-5709150\" style=\"width: 77px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-13-1.png\" alt=\"\">with charge level as a percentage.<\/li>\n\n\n\n<li>If the device is powered by an external power supply, but the APS5 battery is not connected, an<img loading=\"lazy\" decoding=\"async\" width=\"70\" height=\"35\" class=\"wp-image-5709151\" style=\"width: 70px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-14-1.png\" alt=\"\"> icon is shown.<\/li>\n\n\n\n<li>When the external power supply is disconnected, the device switches to the APS5 battery without powering of.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Warning! <\/strong>Charging the APS5 battery from the power bank at an external temperature below 0 \u00b0C (32 \u00b0F) can reduce the battery life. When using external power, connect the Power Bank to the device after it has been turned on and working for several minutes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Getting Started<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Recommended: <\/strong>When using the device for the first time, it is recommended to connect to the Stream Vision 2 app and check for firmware updates. If a newer version is available, the software should be updated.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Charging the battery<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Charge the battery before the first use.<\/li>\n\n\n\n<li>Insert the battery into the battery compartment.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Turning on and adjusting the image<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Open the lens caps. The lens caps can also be removed.<\/li>\n\n\n\n<li>Turn the switch to the <strong>ON<\/strong> position to turn on the device.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"384\" height=\"349\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-15-1.png\" alt=\"\" class=\"wp-image-5709152\"\/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>Adjust the interpupillary distance by moving the eyepieces closer together or further apart.<\/li>\n\n\n\n<li>Adjust the sharpness of the symbols on the displays by rotating the eyepiece diopter adjustment rings. After that, regardless of the distance and other conditions, it is not necessary to rotate the eyepiece diopter adjustment rings.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"502\" height=\"419\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-16-1.png\" alt=\"\" class=\"wp-image-5709153\" style=\"width:497px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-16-1.png 502w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-16-1-400x334.png 400w\" sizes=\"auto, (max-width: 502px) 100vw, 502px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>Press the<strong> DUO <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"31\" height=\"48\" class=\"wp-image-5709154\" style=\"width: 31px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-17-1.png\" alt=\"\">button briefly to select the desired image mode: thermal or digital.<\/li>\n\n\n\n<li>To focus on the object of observation, rotate the focus rings of the thermal imaging <img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"40\" class=\"wp-image-5709155\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-18-1.png\" alt=\"\">or digital<img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"46\" class=\"wp-image-5709156\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-19-1.png\" alt=\"\"> channels, depending on which channel you are using.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"738\" height=\"417\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-20-1.png\" alt=\"\" class=\"wp-image-5709158\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-20-1.png 738w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-20-1-400x226.png 400w\" sizes=\"auto, (max-width: 738px) 100vw, 738px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>If necessary, adjust the brightness<img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"45\" class=\"wp-image-5709159\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-21-1.png\" alt=\"\"> and contrast <img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"44\" class=\"wp-image-5709160\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-22-1.png\" alt=\"\">of the displays in the quick menu (the menu is activated by briefly pressing the button <strong>MENU)<\/strong>.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Observation conditions: time of day, weather, and type of objects being observed affect image quality. The desired quality in a specific situation can be achieved using the microbolometer sensitivity amplification level adjustment function (for thermal imaging mode), IR illuminator settings (radiation power level, focus) for digital mode, as well as user settings for display brightness and contrast.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">DUO mode<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Press and hold the <strong>DUO<\/strong> button to activate the<strong> DUO<\/strong> multispectral mode.<\/li>\n\n\n\n<li>Press the <strong>DUO<\/strong> button briefly to select the PiP window image mode: thermal or digital.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Image adjustment in thermal imaging and thermal imaging DUO modes<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select the calibration mode: manual, semi-automatic, automatic the main menu item<img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"42\" class=\"wp-image-5709161\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-23-1.png\" alt=\"\">(enter the menu by pressing and holding the <strong>MENU <\/strong>button).<\/li>\n\n\n\n<li>Calibrate the thermal imaging by briefly pressing the button<img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"43\" class=\"wp-image-5709162\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-24-1.png\" alt=\"\"> (if <strong>semiautomatic<\/strong> or<strong> manual <\/strong>calibration mode is selected). Close the thermal imaging lens cover before manual calibration.<\/li>\n\n\n\n<li>Select the desired amplification level<img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"44\" class=\"wp-image-5709163\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-25-1.png\" alt=\"\"> by pressing and holding the <strong>MODE<\/strong> button .<\/li>\n\n\n\n<li>To improve the thermal image when increasing the gain level, activate the smoothing filter<img loading=\"lazy\" decoding=\"async\" width=\"59\" height=\"47\" class=\"wp-image-5709164\" style=\"width: 59px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-26-1.png\" alt=\"\"> in the main menu.<\/li>\n\n\n\n<li>Select one of the color palettes <img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"40\" class=\"wp-image-5709165\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-27-1.png\" alt=\"\">by briefly pressing the <strong>MODE <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"66\" class=\"wp-image-5709166\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-28-1.png\" alt=\"\">button.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">IR illuminator<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In <strong>Digital or Digital DUO<\/strong> modes, activate the IR illuminator using one of the following methods:<\/li>\n\n\n\n<li>Press and hold the <strong>MODE <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"66\" class=\"wp-image-5709166\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-28-1.png\" alt=\"\"> button.<\/li>\n\n\n\n<li>Select IR Level in the Quick Menu.<\/li>\n\n\n\n<li>Navigate through the Main Menu: Observation &amp; Zoom Controls \u2192 IR Level.<\/li>\n\n\n\n<li>Press and hold the<strong> MODE<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"66\" class=\"wp-image-5709166\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-28-1.png\" alt=\"\"> button to select one of three IR illuminator power levels. Increasing the power level is necessary when the distance to the observation object increases. This increases the battery discharge rate.<\/li>\n\n\n\n<li>To focus the IR illuminator, move the IR control forward or backward.<\/li>\n\n\n\n<li>To turn off the IR illuminator, press and hold the <strong>MODE<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"66\" class=\"wp-image-5709166\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-28-1.png\" alt=\"\">button when the maximum power level<img loading=\"lazy\" decoding=\"async\" width=\"74\" height=\"40\" class=\"wp-image-5709167\" style=\"width: 74px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-29-1.png\" alt=\"\">is selected.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Laser rangefinder<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Briefly press the <strong>LRF<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"54\" class=\"wp-image-5709168\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-30-1.png\" alt=\"\"> button to turn on the rangefinder. The rangefinder mark will appear in the enter of the display.<\/li>\n\n\n\n<li>Briefly press the <strong>LRF<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"54\" class=\"wp-image-5709168\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-30-1.png\" alt=\"\"> button to measure the distance. If the rangefinder is not used for more than 10 seconds after measurement, it will automatically turn off.<\/li>\n\n\n\n<li>To measure distance in scan mode, press and hold the <strong>LRF<img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"54\" class=\"wp-image-5709168\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-30-1.png\" alt=\"\"> <\/strong>button for 2 seconds.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Proximity sensor<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>To prevent accidental decamouflage of the user, the displays automatically turn off when the observer moves the device away from their face.<\/li>\n\n\n\n<li>When the device is brought close to the face, the displays will automatically turn on.<\/li>\n\n\n\n<li>The proximity sensor is controlled by enabling or disabling Power saving mode<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"38\" class=\"wp-image-5709170\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-31-1.png\" alt=\"\"> in the main menu.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Switching off<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>When you have finished using the device, move the switch to the OFF position to turn off the device.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"384\" height=\"349\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-15-3.png\" alt=\"\" class=\"wp-image-5709173\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Button Operation<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"626\" height=\"373\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-33-1.png\" alt=\"\" class=\"wp-image-5709176\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-33-1.png 626w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-33-1-400x238.png 400w\" sizes=\"auto, (max-width: 626px) 100vw, 626px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Interface<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Status Bar<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"377\" height=\"70\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-34-1.png\" alt=\"\" class=\"wp-image-5709177\" style=\"width:506px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Photo\/video recorder<\/li>\n\n\n\n<li>Microphone<\/li>\n\n\n\n<li>Bluetooth<\/li>\n\n\n\n<li>Wi-Fi connection<\/li>\n\n\n\n<li>Time<\/li>\n\n\n\n<li>Date<\/li>\n\n\n\n<li>Power indication:<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"66\" height=\"36\" class=\"wp-image-5709138\" style=\"width: 66px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-8-1.png\" alt=\"\">\u2013 charge level if the device is powered by a battery<br><img loading=\"lazy\" decoding=\"async\" width=\"70\" height=\"35\" class=\"wp-image-5709151\" style=\"width: 70px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-14-1.png\" alt=\"\">\u2013 charge level if the device is charging and powered by a battery<br><img loading=\"lazy\" decoding=\"async\" width=\"77\" height=\"53\" class=\"wp-image-5709150\" style=\"width: 77px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-13-1.png\" alt=\"\">\u2013 the device operates on an external power supply but is not charging<br><img loading=\"lazy\" decoding=\"async\" width=\"71\" height=\"49\" class=\"wp-image-5709136\" style=\"width: 71px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-5-1.png\" alt=\"\">\u2013 low battery charge<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Thermal imaging mode<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"425\" height=\"122\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-35-1.png\" alt=\"\" class=\"wp-image-5709178\" style=\"width:530px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-35-1.png 425w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-35-1-400x115.png 400w\" sizes=\"auto, (max-width: 425px) 100vw, 425px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Image stabilization<\/li>\n\n\n\n<li>Amplification level<\/li>\n\n\n\n<li>Magnification in thermal\/digital channel<\/li>\n\n\n\n<li>Smoothing filter<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Digital mode<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"398\" height=\"136\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-36-1.png\" alt=\"\" class=\"wp-image-5709179\" style=\"width:433px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Image stabilization<\/li>\n\n\n\n<li>Modes:<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"51\" height=\"50\" class=\"wp-image-5709184\" style=\"width: 51px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-37-1.png\" alt=\"\">Day Color \u2013 color image<br><img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"47\" class=\"wp-image-5709181\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-38-1.png\" alt=\"\">Twilight \u2013 color image in low light conditions<br><img loading=\"lazy\" decoding=\"async\" width=\"44\" height=\"44\" class=\"wp-image-5709182\" style=\"width: 44px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-39-1.png\" alt=\"\">Night B&amp;W \u2013 monochrome black-and-white image<br><img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"46\" class=\"wp-image-5709183\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-40-1.png\" alt=\"\">Night Green \u2013 monochrome green image<\/p>\n\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li>Magnification in digital\/thermal channel<\/li>\n\n\n\n<li>IR-Illuminator power levels<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Quick Menu<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Quick Menu gives you instant access to the most important device settings, letting you adjust key parameters quickly without opening the main menu. It\u2019s designed for fast, on-the-go changes to brightness, contrast, sensitivity amplification levels, and IR illuminator power<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"553\" height=\"415\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-41-1.png\" alt=\"\" class=\"wp-image-5709185\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-41-1.png 553w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-41-1-400x300.png 400w\" sizes=\"auto, (max-width: 553px) 100vw, 553px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>How to open the Quick Menu:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Briefly press the <strong>MENU <\/strong>button.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Navigation:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>To switch between settings, press the <strong>MENU <\/strong>button repeatedly.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Available settings:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Brightness <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"45\" class=\"wp-image-5709186\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-21-2.png\" alt=\"\"><strong>:<\/strong> Rotate the controller ring<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"48\" class=\"wp-image-5709187\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-42-1.png\" alt=\"\"> to set the display brightness level from 0 to 20.<\/li>\n\n\n\n<li><strong>Contrast<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"44\" class=\"wp-image-5709160\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-22-1.png\" alt=\"\"><strong> : <\/strong>Rotate the controller ring <img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"48\" class=\"wp-image-5709187\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-42-1.png\" alt=\"\">to set the display contrast level from 0 to 20.<\/li>\n\n\n\n<li><strong>Sensitivity amplification levels <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"44\" class=\"wp-image-5709163\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-25-1.png\" alt=\"\"><strong>: <\/strong>Select one of three levels for the thermal imaging channel \u2014 Normal, High, Ultra.<\/li>\n\n\n\n<li><strong>IR illuminator power<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"59\" height=\"42\" class=\"wp-image-5709188\" style=\"width: 59px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-45-1.png\" alt=\"\"><strong> : <\/strong>Adjust the IR power level (Low \/ Medium \/ High) depending on observation conditions and distance to the object.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>How to exit the Quick Menu:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Press the<strong> BACK<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"50\" class=\"wp-image-5709189\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-46-1.png\" alt=\"\"><strong> <\/strong>button or wait 5 seconds for automatic exit.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Main Menu<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The main menu provides access to the full range of settings and functions of the device. It includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Observation &amp; Zoom Controls<\/li>\n\n\n\n<li>Image settings<\/li>\n\n\n\n<li>Device settings<\/li>\n\n\n\n<li>Media<\/li>\n\n\n\n<li>System settings<\/li>\n<\/ul>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>To enter the main menu,<\/strong> press and hold the <strong>MENU<\/strong> button until the menu appears on the screen.<\/li>\n\n\n\n<li><strong>Navigate through the menu items<\/strong> by rotating the controller ring<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"48\" class=\"wp-image-5709187\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-42-1.png\" alt=\"\"> .<\/li>\n\n\n\n<li><strong>To select a menu item or confirm selection<\/strong>, press the <strong>MENU<\/strong><\/li>\n\n\n\n<li><strong>To return to the previous level or exit the menu<\/strong>, press the <strong>BACK<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"50\" class=\"wp-image-5709189\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-46-1.png\" alt=\"\"> or press and hold the <strong>MENU<\/strong><\/li>\n\n\n\n<li>If no actions are performed within 10 seconds, the menu will close automatically.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong> When entering the main menu, the background image darkens to improve menu visibility. This is a normal feature and not a defect.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Observation &amp; Zoom Controls<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Laser rangefinder<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Reticle type<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Reticle Type<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"39\" class=\"wp-image-5709190\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-47-1.png\" alt=\"\"> menu item allows you to select one of the three reticle shapes<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Target position angle<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Function Target Position Angle<img loading=\"lazy\" decoding=\"async\" width=\"46\" height=\"41\" class=\"wp-image-5709191\" style=\"width: 46px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-48-1.png\" alt=\"\"> allows you to measure the angle of target location (angle of elevation). When the function is activated, the angle is shown continuously.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"533\" height=\"408\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-49-1.png\" alt=\"\" class=\"wp-image-5709192\" style=\"width:543px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-49-1.png 533w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-49-1-400x306.png 400w\" sizes=\"auto, (max-width: 533px) 100vw, 533px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">True distance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">True Horizontal Distance <img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"52\" class=\"wp-image-5709193\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-50-1.png\" alt=\"\">function allows you to measure true horizontal distance to a target based on the angle of elevation value.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When activated, the message <strong>THD <\/strong>will appear above the distance reading.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"555\" height=\"411\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-51-1.png\" alt=\"\" class=\"wp-image-5709194\" style=\"width:569px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-51-1.png 555w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-51-1-400x296.png 400w\" sizes=\"auto, (max-width: 555px) 100vw, 555px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Picture-in-Picture<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PiP (\u201cPicture-in-Picture\u201d) allows you to see a zoomed image simultaneously with the main image in a dedicated window.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"524\" height=\"419\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-52-1.png\" alt=\"\" class=\"wp-image-5709195\" style=\"width:534px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-52-1.png 524w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-52-1-400x320.png 400w\" sizes=\"auto, (max-width: 524px) 100vw, 524px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>Turn on\/off the PiP function with a long press of <strong>BACK<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"50\" class=\"wp-image-5709189\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-46-1.png\" alt=\"\">button or in the main menu:<strong> Observation and Zoom Controls<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"51\" height=\"31\" class=\"wp-image-5709198\" style=\"width: 51px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-151.png\" alt=\"\"><strong> \u2013&gt; Picture<\/strong>&#8211;<strong>in-picture<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"44\" height=\"42\" class=\"wp-image-5709199\" style=\"width: 44px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-54-1.png\" alt=\"\"><strong> .<\/strong><\/li>\n\n\n\n<li>Change zoom ratio in the PiP window with a rotation of the controller ring <img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"48\" class=\"wp-image-5709187\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-42-1.png\" alt=\"\">.<\/li>\n\n\n\n<li>The zoomed image is displayed in a dedicated window, while the image in the rest of the screen is displayed at base magnification.<\/li>\n\n\n\n<li>When PiP is turned on, you can operate the discrete and continuous digital zoom. The magnification will take place only in the dedicated window.<\/li>\n\n\n\n<li>When PiP is turned off, the image is shown with the optical magnification set for the PiP function.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Zoom on button press<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If enabled, smooth zooming starts after pressing the <strong>BACK<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"50\" class=\"wp-image-5709189\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-46-1.png\" alt=\"\"> <\/strong>button and then rotating the controller ring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If disabled, zoom level can be adjusted directly by rotating the controller ring without pressing the <strong>BACK<strong><img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"50\" class=\"wp-image-5709189\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-46-1.png\" alt=\"\"><\/strong>  <\/strong>button.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IR level<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In <strong>digital <\/strong>and <strong>digital DUO<\/strong> modes, this menu item <img loading=\"lazy\" decoding=\"async\" width=\"59\" height=\"42\" class=\"wp-image-5709200\" style=\"width: 59px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-45-2.png\" alt=\"\">lets you set the IR illuminator power level or switch it off.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">External Ballistics<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Ballistics activation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The item<img loading=\"lazy\" decoding=\"async\" width=\"48\" height=\"46\" class=\"wp-image-5709201\" style=\"width: 48px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-56-1.png\" alt=\"\"> enables\/disables the Ballistic calculator function to show the<br>recommended aiming point and correction values. For more information on using the function, see the section Ballistics calculator.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"522\" height=\"398\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-135.png\" alt=\"\" class=\"wp-image-5709115\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-135.png 522w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-135-400x305.png 400w\" sizes=\"auto, (max-width: 522px) 100vw, 522px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Ballistic profiles<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This item <img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"42\" class=\"wp-image-5709203\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-58-1.png\" alt=\"\">allows you to select one of five profiles (\u0410, \u0412, \u0421, D, E) to use in the ballistics calculator.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Calculator units<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Choose units for ballistic corrections<img loading=\"lazy\" decoding=\"async\" width=\"47\" height=\"45\" class=\"wp-image-5709204\" style=\"width: 47px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-59-1.png\" alt=\"\"><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>MOA<\/li>\n\n\n\n<li>MRAD<\/li>\n\n\n\n<li>Click<\/li>\n\n\n\n<li>mm\/cm (default)<\/li>\n\n\n\n<li>inch<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Image Settings<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Image Settings<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"45\" class=\"wp-image-5709186\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-21-2.png\" alt=\"\">allows adjustment display brightness from 0 to 20.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contrast<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"44\" class=\"wp-image-5709160\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-22-1.png\" alt=\"\">allows adjustment display contrast from 0 to 20.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Save thermal image settings<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If <img loading=\"lazy\" decoding=\"async\" width=\"54\" height=\"47\" class=\"wp-image-5709207\" style=\"width: 54px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-62-1.png\" alt=\"\">enabled, the device will restore the previously saved brightness and contrast values for the thermal channel when powered on again. If disabled, default brightness and contrast values for the selected palette will be applied.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Available palettes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In this section, you can select colour palettes<img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"40\" class=\"wp-image-5709165\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-27-1.png\" alt=\"\"> that can be switched by pressing the <strong>MODE<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"66\" class=\"wp-image-5709166\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-28-1.png\" alt=\"\">button.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"573\" height=\"422\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-61-1.png\" alt=\"\" class=\"wp-image-5709208\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-61-1.png 573w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-61-1-400x295.png 400w\" sizes=\"auto, (max-width: 573px) 100vw, 573px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">The user can disable all palettes except one. If the active palette is disabled, it will remain in use until the user presses the button. After that, the palette is removed from the switching cycle.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To preserve brightness in contrast values wehen swiching palettes activate <strong>Save thermal image settings<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"54\" height=\"47\" class=\"wp-image-5709207\" style=\"width: 54px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-62-1.png\" alt=\"\"><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"519\" height=\"392\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-63-1.png\" alt=\"\" class=\"wp-image-5709211\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-63-1.png 519w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-63-1-400x302.png 400w\" sizes=\"auto, (max-width: 519px) 100vw, 519px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Available colour palettes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>White hot<\/li>\n\n\n\n<li>Black hot<\/li>\n\n\n\n<li>Green<\/li>\n\n\n\n<li>Red Hot<\/li>\n\n\n\n<li>Red Monochrome<\/li>\n\n\n\n<li>Rainbow<\/li>\n\n\n\n<li>Ultramarine<\/li>\n\n\n\n<li>Violet<\/li>\n\n\n\n<li>Sepia<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Amplification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The Normal<img loading=\"lazy\" decoding=\"async\" width=\"66\" height=\"41\" class=\"wp-image-5709214\" style=\"width: 66px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-65-1.png\" alt=\"\"> , <img loading=\"lazy\" decoding=\"async\" width=\"66\" height=\"41\" class=\"wp-image-5709214\" style=\"width: 66px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-65-1.png\" alt=\"\">High , Ultra<img loading=\"lazy\" decoding=\"async\" width=\"69\" height=\"41\" class=\"wp-image-5709215\" style=\"width: 69px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-66-1.png\" alt=\"\"> sensitivity nhancement features are the latest in software algorithm offerings from Pulsar that enhance the quality of detection and object recognition, regardless of observation conditions. When the temperature contrast decreases due to conditions such as fog, recipitation or high humidity, increasing the amplification level can optimize the image picture. To reduce digital distortion, activate the <strong>Smoothing <\/strong>in the main menu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Option 1: <\/strong>Press and hold the <strong>MODE <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"66\" class=\"wp-image-5709166\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-28-1.png\" alt=\"\">button to switch the mplification level.<br><strong>Option 2: <\/strong>Choose amplification level in the main menu:<strong> Image settings<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"94\" height=\"42\" class=\"wp-image-5709216\" style=\"width: 94px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-67-1.png\" alt=\"\"><strong>Amplification<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"44\" class=\"wp-image-5709163\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-25-1.png\" alt=\"\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Smoothing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The<strong> Smoothing<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"59\" height=\"47\" class=\"wp-image-5709164\" style=\"width: 59px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-26-1.png\" alt=\"\"> function refines the image and makes the thermal picture appear smoother and more uniform. When smoothing is enabled, the image looks less grainy and more comfortable for long-term observation, especially on uniform backgrounds.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Display dimming<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The<strong> Dimming function<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"35\" class=\"wp-image-5709219\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-153.png\" alt=\"\">is designed to reduce the brightness of the display when using the device in the dark to reduce eye strain. The Interface brightness value in dimming mode will be retained when the function is turned on again. The Interface brightness value in dimming mode will be retained when the function is turned on again.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Interface brightness<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Adjusting the<strong> Interface brightness<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"55\" height=\"46\" class=\"wp-image-5709217\" style=\"width: 55px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-68-1.png\" alt=\"\"> helps ensure comfortable viewing in any lighting conditions. Increase brightness for daytime use or lower it at night to minimize glare and reduce eye strain.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Screen shape<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The<strong> Screen shape<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"43\" class=\"wp-image-5709220\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-24-2.png\" alt=\"\"> option allows the user to select the shape of the screen contour (Rounded, Circular) to adapt the interface to their individual preferences.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong><br>Photos and videos are always recorded in a rectangular shape, regardless of the selected screen shape.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Image stabilization<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Image stabilization reduces image shake when observing handheld, especially at high magnification or during long observations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Activation<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>By long-pressing the Stabilization button <img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"43\" class=\"wp-image-5709220\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-24-2.png\" alt=\"\">on the device body.<\/li>\n\n\n\n<li>In the main menu:<strong> Image settings <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"94\" height=\"42\" class=\"wp-image-5709216\" style=\"width: 94px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-67-1.png\" alt=\"\"><strong>Image stabilization <\/strong>&gt; <strong>Activation<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"37\" class=\"wp-image-5709222\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-71-1.png\" alt=\"\"><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note: <\/strong>the image stabilization function is automatically switched off <img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"40\" class=\"wp-image-5709223\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-154.png\" alt=\"\">during laser rangefinder operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Calibrate<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If performance of Electronic Image Stabilization (EIS) decreases during long-term use, it is recommended to perform calibration<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"42\" class=\"wp-image-5709224\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-72-1.png\" alt=\"\"> . For this put device on the smooth surface and press \u201cCalibrate\u201d. It will take up to 10 seconds<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"545\" height=\"430\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-73-1.png\" alt=\"\" class=\"wp-image-5709225\" style=\"width:568px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-73-1.png 545w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-73-1-400x316.png 400w\" sizes=\"auto, (max-width: 545px) 100vw, 545px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Device Settings<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Bluetooth<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Activate Bluetooth<img loading=\"lazy\" decoding=\"async\" width=\"31\" height=\"46\" class=\"wp-image-5709226\" style=\"width: 31px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-74-1.png\" alt=\"\"> module to connect the device to the SV Ballistics obile App.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Bluetooth settings<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Turn on the Bluetooth module inthe main menu: <strong>Device settings<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"81\" height=\"63\" class=\"wp-image-5709227\" style=\"width: 81px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-138-1.png\" alt=\"\">Bluetooth<br>.<\/li>\n\n\n\n<li>Go to <strong>Device settings <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"81\" height=\"63\" class=\"wp-image-5709227\" style=\"width: 81px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-138-1.png\" alt=\"\"><strong> Bluetooth pairing <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"51\" height=\"47\" class=\"wp-image-5709228\" style=\"width: 51px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-78-1.png\" alt=\"\">to activate pairing.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"515\" height=\"401\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-79-1.png\" alt=\"\" class=\"wp-image-5709230\" style=\"width:518px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-79-1.png 515w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-79-1-400x311.png 400w\" sizes=\"auto, (max-width: 515px) 100vw, 515px\" \/><\/figure>\n<\/div>\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li>Turn on Bluetooth on your smartphone.<\/li>\n\n\n\n<li>Connect your smartphone to the device using the Stream Vision Ballistics App (Devices tab &gt; Connect Device button).<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"193\" height=\"396\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-80-1.png\" alt=\"\" class=\"wp-image-5709231\" style=\"width:220px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">5. Click \u201cConnect\u201d next to your device.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"192\" height=\"393\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-81-1.png\" alt=\"\" class=\"wp-image-5709232\" style=\"width:213px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<ol start=\"6\" class=\"wp-block-list\">\n<li>Enter the code from the device screen in the Stream Vision Ballistics App and tap \u201cConnect\u201d.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"520\" height=\"408\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-82-1.png\" alt=\"\" class=\"wp-image-5709233\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-82-1.png 520w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-82-1-400x314.png 400w\" sizes=\"auto, (max-width: 520px) 100vw, 520px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"198\" height=\"398\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-83-1.png\" alt=\"\" class=\"wp-image-5709234\" style=\"width:207px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">The blue Bluetooth icon <img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"39\" class=\"wp-image-5709235\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-155.png\" alt=\"\">next to the device means that the device is connected.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"197\" height=\"401\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-84-1.png\" alt=\"\" class=\"wp-image-5709236\" style=\"width:217px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Wi-Fi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Activate <strong>Wi-Fi<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"37\" height=\"40\" class=\"wp-image-5709238\" style=\"width: 37px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-85-1.png\" alt=\"\"><strong> <\/strong>to connect the device to the Stream Vision 2 application on your smartphone. This enables remote control of the device and provides access to additional features via the app.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Wi-Fi Settings<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Password Setup<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This menu option<img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709239\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-86-1.png\" alt=\"\"> allows you to set a password for accessing your Pulsar device from an external device. The password is unique for each device.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Access Level Setup<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This menu option <img loading=\"lazy\" decoding=\"async\" width=\"49\" height=\"43\" class=\"wp-image-5709240\" style=\"width: 49px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-87-1.png\" alt=\"\">allows you to set the required access level for the Stream Vision 2 application:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Owner: <\/strong>Full access to all device functions.<\/li>\n\n\n\n<li><strong>Guest: <\/strong>Access to real-time video streaming only.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Wi-Fi Band<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This setting<img loading=\"lazy\" decoding=\"async\" width=\"46\" height=\"35\" class=\"wp-image-5709241\" style=\"width: 46px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-88-1.png\" alt=\"\">helps resolve smartphone connection issues in the following cases:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>If your smartphone does not support the 5 GHz Wi-Fi band, switch to 2.4 GHz.<\/li>\n\n\n\n<li>If there is interference from multiple Wi-Fi networks, switching between Wi-Fi bands can improve the connection between the device and your smartphone.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Calibration<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Calibration equalizes the microbolometer\u2019s background temperature and<br>eliminates image flaws such as vertical bars and phantom images on the thermal image. There are three calibration modes: <strong>Automatic, Semi-Automatic<\/strong> and<strong> Manual:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Automatic<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The device calibrates itself automatically according to firmware algorithms.<\/li>\n\n\n\n<li>There is no need to close the lens cover; an internal shutter automatically covers the microbolometer.<\/li>\n\n\n\n<li>The user can also initiate calibration manually by pressing the <strong>Calibration<\/strong> button<img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"43\" class=\"wp-image-5709220\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-24-2.png\" alt=\"\"> (as in SA mode).<\/li>\n\n\n\n<li>A countdown timer appears on the right side of the screen when 5 seconds remain before automatic calibration.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Manual Mode<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Close the thermal imaging channel lens cover.<\/li>\n\n\n\n<li>Briefly press the <strong>Calibration<\/strong> button <img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"43\" class=\"wp-image-5709220\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-24-2.png\" alt=\"\">.<\/li>\n\n\n\n<li>Open the lens cover after calibration is complete<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Notes:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>During calibration, the image on the display may freeze for up to 1 second.<\/li>\n\n\n\n<li>The selected calibration mode is retained after restarting the device.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">No-use shutdown<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The No Use Shutdown<img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"47\" class=\"wp-image-5709242\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-91-1.png\" alt=\"\"> function automatically turns off the device after 30 minutes of inactivity in Power saving mode or Sleep mode. If no buttons are pressed and no actions are performed during this period, the device will power off to conserve battery life.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Control preference<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The<strong> Control Preferences<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"46\" class=\"wp-image-5709243\" style=\"width: 42px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-92-1.png\" alt=\"\"><strong> <\/strong>function lets you mirror the button layout for lefthanded users or keep the standard layout for right-handed users.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Haptic vibro indication<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function<img loading=\"lazy\" decoding=\"async\" width=\"64\" height=\"44\" class=\"wp-image-5709244\" style=\"width: 64px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-93-1.png\" alt=\"\"> enables vibration feedback when the device is turned on or off, and when buttons are pressed<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Power saving mode<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When Power<strong> Saving Mode<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"49\" height=\"34\" class=\"wp-image-5709245\" style=\"width: 49px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-94-1.png\" alt=\"\"> is on, the device helps save battery as follows:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Power Saving Mode<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The displays turn off if you move the device away from your eyes for more than 5 seconds.<\/li>\n\n\n\n<li>Video recording and streaming can continue if they were active.<\/li>\n\n\n\n<li>Wi-Fi and Bluetooth stay on.<\/li>\n\n\n\n<li>To turn the displays back on, just bring the device to your eyes or press any button.<\/li>\n\n\n\n<li>If video recording, streaming, or file transfer is not active, and you keep the device away from your eyes for more than 5 seconds, Power Saving Mode will automatically switch to Sleep Mode for maximum battery saving.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Sleep Mode<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">You can activate at any time by turning the switch on the device to the Sleep position, even if Power Saving Mode is off.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"356\" height=\"355\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-95-1.png\" alt=\"\" class=\"wp-image-5709246\" style=\"width:360px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-95-1.png 356w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-95-1-300x300.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>The displays turn off.<\/li>\n\n\n\n<li>Wi-Fi and Bluetooth are turned off.<\/li>\n\n\n\n<li>IR illuminator and rangefinder are turned off.<\/li>\n\n\n\n<li>Video recording and USB streaming stop.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Media<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Record with sound<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function allows you to enable the microphone<img loading=\"lazy\" decoding=\"async\" width=\"35\" height=\"50\" class=\"wp-image-5709247\" style=\"width: 35px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-96-1.png\" alt=\"\"> to record video with sound.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Video compression<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This setting allows you to choose the level of video compression<img loading=\"lazy\" decoding=\"async\" width=\"54\" height=\"44\" class=\"wp-image-5709248\" style=\"width: 54px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-97-1.png\" alt=\"\"> to balance between file size and video quality.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ON:<\/strong> Standard compression is applied.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Video files take up less space.<\/li>\n\n\n\n<li>You can store more videos on the device.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>OFF<\/strong>: Minimal compression is applied.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Video quality is higher.<\/li>\n\n\n\n<li>Video files are much larger and take up more space.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note: <\/strong>Larger video file sizes result in shorter available recording times and may increase the download time for video files when using the Stream Vision 2 app.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Format media disk<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function<img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"46\" class=\"wp-image-5709249\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-98-1.png\" alt=\"\"> erases all files from the device\u2019s internal memory. Use this option to quickly clear all recorded videos and photos. Formatting should be performed if a memory error occurs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong> All data will be permanently deleted and cannot be restored. Before formatting, make sure to transfer important files to another device.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">System Settings<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Language<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function<img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"45\" class=\"wp-image-5709250\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-99-1.png\" alt=\"\"> allows you to select the device\u2019s menu language from the following options: English, German, Spanish, French, Russian, Italian, Portuguese, Dutch, Danish, Norwegian, Swedish, Polish, Czech, Hungarian, Lithuanian, Latvian, Bulgarian, Finnish, and Ukrainian.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Date<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function<img loading=\"lazy\" decoding=\"async\" width=\"48\" height=\"46\" class=\"wp-image-5709251\" style=\"width: 48px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-100-1.png\" alt=\"\"> lets you set the current date in the device. The date is shown in the status bar and is used for naming videos and photos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Time<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function <img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"46\" class=\"wp-image-5709252\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-101-1.png\" alt=\"\">lets you set the current time on the device. The time is shown in the status bar and is sed for naming videos and photos. You can choose between 12-hour and 24-hour formats.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Units of measurement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function lets you choose the units for distance displayed in the laser<br>rangefinder widget. You can select either meters or yards.<img loading=\"lazy\" decoding=\"async\" width=\"46\" height=\"44\" class=\"wp-image-5709253\" style=\"width: 46px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-102-1.png\" alt=\"\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Reset to default settings<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This function <img loading=\"lazy\" decoding=\"async\" width=\"40\" height=\"41\" class=\"wp-image-5709256\" style=\"width: 40px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-156.png\" alt=\"\">restores all device settings to their original factory values. The reset cannot be undone. All your custom settings will be erased.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong> When restoring the factory defaults, the date, time, and user pixel map are saved.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Image pixel repair<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When using the thermal imager, you may notice defective (dead) pixels \u2014 bright or dark dots that do not change brightness. Defective pixels on the microbolometer can increase in size relative to the digital-zoom<br>power. The Pixel Repair function allows you to mask these pixels on the image. How it works:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Go to the menu: <strong>System settings <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"81\" height=\"39\" class=\"wp-image-5709257\" style=\"width: 81px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-106-1.png\" alt=\"\"> <strong>Image pixel repair<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"81\" height=\"43\" class=\"wp-image-5709258\" style=\"width: 81px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-104-1.png\" alt=\"\"><strong>Pixel Repair<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"42\" class=\"wp-image-5709259\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-105-1.png\" alt=\"\"> and use a movable marker to select a defective pixel on the display.<\/li>\n\n\n\n<li>A magnified area helps you precisely align the marker with the defective pixel.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"522\" height=\"408\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-107-1.png\" alt=\"\" class=\"wp-image-5709260\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-107-1.png 522w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-107-1-400x313.png 400w\" sizes=\"auto, (max-width: 522px) 100vw, 522px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>Move the marker by rotating the controller. To switch between vertical and horizontal movement, press the <strong>MENU <\/strong>button. The x and y coordinates are shown in the widget below the magnified area.<\/li>\n\n\n\n<li>Once aligned, remove (mask) the defective pixel by pressing the <strong>REC <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"49\" height=\"45\" class=\"wp-image-5709261\" style=\"width: 49px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-115-1.png\" alt=\"\">button. An \u201cOK\u201d message will confirm the action.<\/li>\n\n\n\n<li>To save the pixel map and exit the menu, press the <strong>BACK<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"50\" class=\"wp-image-5709189\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-46-1.png\" alt=\"\"> button.<\/li>\n\n\n\n<li>You can repeat the process for other defective pixels.<\/li>\n\n\n\n<li>All masked pixels are saved in the device\u2019s memory and added to the factory pixel map.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note: <\/strong>While in the Pixel Repair menu, other device functions are temporarily unavailable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Restore default pixel map<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If needed, you can restore the original factory pixel map<img loading=\"lazy\" decoding=\"async\" width=\"40\" height=\"41\" class=\"wp-image-5709256\" style=\"width: 40px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-156.png\" alt=\"\"> through the menu. This will remove all user-masked pixels and return the display to its original state.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Device information<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This option<img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"40\" class=\"wp-image-5709262\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-109-1.png\" alt=\"\">allows you to view important details about your device, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Full name<\/li>\n\n\n\n<li>SKU number<\/li>\n\n\n\n<li>Serial number<\/li>\n\n\n\n<li>Firmware version<\/li>\n\n\n\n<li>Hardware version<\/li>\n\n\n\n<li>Service information<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Functions<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Video Recording and Photography<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Symbion LRF<\/strong> binoculars feature video recording and photography of the image being ranged to the internal memory card. Before using the photo and video functions, setup the Date<img loading=\"lazy\" decoding=\"async\" width=\"48\" height=\"46\" class=\"wp-image-5709263\" style=\"width: 48px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-100-2.png\" alt=\"\"> and Time<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"46\" class=\"wp-image-5709264\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-101-2.png\" alt=\"\"> in the <strong>System Settings <\/strong>.<img loading=\"lazy\" decoding=\"async\" width=\"29\" height=\"32\" class=\"wp-image-5709265\" style=\"width: 29px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-157.png\" alt=\"\"><br>For information on how to watch recorded photos and videos, see the Stream Vision 2 user manual: Android, iOS. The built-in recorder operates in two modes \u2013 <strong>Video<\/strong> and<strong> Photo.<\/strong> Built-in recorder operates in two modes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Photo<\/strong> (photography; the icon <img loading=\"lazy\" decoding=\"async\" width=\"52\" height=\"49\" class=\"wp-image-5709266\" style=\"width: 52px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-112-1.png\" alt=\"\">is displayed in the upper left corner of the image).<\/li>\n\n\n\n<li><strong>Video<\/strong> (video recording; the icon <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"40\" class=\"wp-image-5709267\" style=\"width: 50px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-113-1.png\" alt=\"\">is displayed in the upper left corner of the<\/li>\n\n\n\n<li>image, the total remaining recording time is given taking into account the current resolution in the HH:MM format (hours:minutes)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Switching between the operating modes of the video recorder is done by long pressing<br>the <img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\"> button. Switching between the modes is cyclical<strong> (Video\u2013&gt;Photo\u2013Video)<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Photo mode. Capturing an image<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"536\" height=\"401\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-114-1.png\" alt=\"\" class=\"wp-image-5709271\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-114-1.png 536w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-114-1-400x299.png 400w\" sizes=\"auto, (max-width: 536px) 100vw, 536px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Switch to the <strong>Photo<\/strong> mode with a long press of the <strong>REC<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\"> button.<\/li>\n\n\n\n<li>Press the <strong>REC<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\"> button briefly to capture a photo. The icon<img loading=\"lazy\" decoding=\"async\" width=\"52\" height=\"49\" class=\"wp-image-5709266\" style=\"width: 52px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-112-1.png\" alt=\"\"> flashes \u2013 the photo file is being saved to the built-in SD card.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Video mode. Recording a video<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"533\" height=\"403\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-116-2.png\" alt=\"\" class=\"wp-image-5709270\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-116-2.png 533w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-116-2-400x302.png 400w\" sizes=\"auto, (max-width: 533px) 100vw, 533px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Switch to the <strong>Video<\/strong> mode with a long press of the <strong>REC<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\">button.<\/li>\n\n\n\n<li>Press the <strong>REC <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\">button briefly to start video recording.<\/li>\n\n\n\n<li>When the video recording starts, the icon <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"40\" class=\"wp-image-5709267\" style=\"width: 50px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-113-1.png\" alt=\"\">will disappear, instead of it an icon with a timer in the MM:SS (minutes:seconds) format will appear<img loading=\"lazy\" decoding=\"async\" width=\"70\" height=\"36\" class=\"wp-image-5709272\" style=\"width: 70px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-117-1.png\" alt=\"\"> .<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"464\" height=\"347\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-158.png\" alt=\"\" class=\"wp-image-5709273\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-158.png 464w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-158-400x299.png 400w\" sizes=\"auto, (max-width: 464px) 100vw, 464px\" \/><\/figure>\n<\/div>\n\n\n<ol start=\"4\" class=\"wp-block-list\">\n<li>Pause\/continue recording by briefly pressing the <strong>REC<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\">button.<\/li>\n\n\n\n<li>Press and hold the<strong> REC<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\">button to stop video recording. Video files are stored in the built-in memory card:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>After turning off the video recording;<\/li>\n\n\n\n<li>Upon powering the device off if recording was on;<\/li>\n\n\n\n<li>When the memory card is overfilled during recording (Memory Full message appears)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Notes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>You can enter and navigate the menu during video recording.<\/li>\n\n\n\n<li>Recorded videos and photos are saved to the built-in memory card of the device in the format img_xxx. jpg (for photos); video_xxx. mp4 (for video).<\/li>\n\n\n\n<li>Videos are recorded in clips with a maximum duration of 5 minutes. The number of recorded files is limited by the capacity of unit\u2019s internal memory and video compression ratio.<\/li>\n\n\n\n<li>Regularly check free memory within the built-in memory card and move the footage to other storage media to free up the memory card space.<\/li>\n\n\n\n<li>In case of a memory card error, you can use the format function in the <strong>Media<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"40\" class=\"wp-image-5709267\" style=\"width: 50px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-113-1.png\" alt=\"\"> section of the main menu.<\/li>\n\n\n\n<li>When the <strong>Power saving mode<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"38\" class=\"wp-image-5709170\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-31-1.png\" alt=\"\"> is activated, video recording continues to run in the background.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Using the Laser Rangefinder<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The binoculars are equipped with a built-in rangefinder, allowing you to measure distance to objects up to 1500 m away.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How the rangefinder works<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Turn on the device, set up image according to section Getting Started.<\/li>\n\n\n\n<li>Briefly press the<strong> LRF<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"54\" class=\"wp-image-5709168\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-30-1.png\" alt=\"\">button to measure the distance. The rangefinder reticle will appear in the centre of the image. In the bottom of the display you will see distance in meters (or yards \u2013 depending on settings).<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"529\" height=\"411\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-118-1.png\" alt=\"\" class=\"wp-image-5709274\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-118-1.png 529w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-118-1-400x311.png 400w\" sizes=\"auto, (max-width: 529px) 100vw, 529px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">3. Point the rangefinding reticle at an object and press the <strong>LRF<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"54\" class=\"wp-image-5709168\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-30-1.png\" alt=\"\"> button.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Operation in SCAN mode<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>To measure distance in scanning mode, hold down the <strong>LRF<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"54\" class=\"wp-image-5709168\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-30-1.png\" alt=\"\">button for longer than two seconds. Measurement readings will be changing in real time as you point the binoculars at different objects. The text in the LRF widget will become green.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"532\" height=\"416\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-120-1.png\" alt=\"\" class=\"wp-image-5709275\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-120-1.png 532w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-120-1-400x313.png 400w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><\/figure>\n<\/div>\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li>If measurement fails, dashes will appear on the display.<\/li>\n\n\n\n<li>To turn off the rangefinder, press <strong>LRF<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"38\" height=\"54\" class=\"wp-image-5709168\" style=\"width: 38px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-30-1.png\" alt=\"\">button again.<\/li>\n\n\n\n<li>In 10 seconds of inactivity (no measurement is taken) the rangefinder turns off, the rangefinding reticle with readings disappears from the display.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Notes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The rangefinding reticle can be changed in the<strong> Observation &amp; Zoom Controls<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"92\" height=\"33\" class=\"wp-image-5709278\" style=\"width: 92px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-159-1.png\" alt=\"\"> Laser rangefinder <img loading=\"lazy\" decoding=\"async\" width=\"63\" height=\"34\" class=\"wp-image-5709279\" style=\"width: 63px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-160.png\" alt=\"\"> <strong>Reticle Type<\/strong> .<img loading=\"lazy\" decoding=\"async\" width=\"37\" height=\"34\" class=\"wp-image-5709280\" style=\"width: 37px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-161.png\" alt=\"\"><\/li>\n\n\n\n<li>Units of measurement (meters or yards) can be changed in see the <strong>System<\/strong> <strong>Settings<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"81\" height=\"39\" class=\"wp-image-5709257\" style=\"width: 81px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-106-1.png\" alt=\"\"> Units of measurement <img loading=\"lazy\" decoding=\"async\" width=\"46\" height=\"44\" class=\"wp-image-5709253\" style=\"width: 46px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-102-1.png\" alt=\"\">section. Additional Information:<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Accuracy of measurement and maximum range depend on the reflection ratio of the target surface, the  angle at which the emitting beam falls on the target surface and environmental conditions. Reflectivity is also affected by surface texture, color, size and shape of the target. A shiny or brightly colored surface is normally more reflective than a dark surface.<\/li>\n\n\n\n<li>Measuring range to a small sized target is more difficult than to a large sized target.<\/li>\n\n\n\n<li>Accuracy of measurement can also be affected by light conditions, fog, haze, rain, snow etc. Ranging performance can degrade in bright conditions or when ranging towards the sun.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Ballistics calculator<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Install the Stream Vision Ballistics app from Google Play or AppStore.<\/li>\n\n\n\n<li>Go to Profiles tab<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"190\" height=\"400\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-123-1.png\" alt=\"\" class=\"wp-image-5709281\" style=\"width:207px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li>Create a profile for your riflescope, ammunition and zeroing distance. Make sure that \u201cBallistic parameters\u201d switch is on. If your ammo is not on the list, you can enter its parameters manually. The more arameters you specify, the more accurate the recommended point of aiming will be.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"196\" height=\"396\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-124-2.png\" alt=\"\" class=\"wp-image-5709284\" style=\"width:212px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">If you select a riflescope model, you will be able to display the correction values in clicks.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"201\" height=\"403\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-125-2.png\" alt=\"\" class=\"wp-image-5709285\" style=\"width:211px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-125-2.png 201w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-125-2-200x400.png 200w\" sizes=\"auto, (max-width: 201px) 100vw, 201px\" \/><\/figure>\n<\/div>\n\n\n<ol start=\"4\" class=\"wp-block-list\">\n<li>Adjust the temperature, pressure and humidity of the environment while zeroing your riflescope.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"198\" height=\"395\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-126-1.png\" alt=\"\" class=\"wp-image-5709286\" style=\"width:220px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li>Enter a profile name and click save.<\/li>\n\n\n\n<li>Connect your device to your smartphone using Bluetooth.<\/li>\n\n\n\n<li>Load the profile into the device.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">To do this, go to the \u201cDevices\u201d tab \u2013&gt; Select your device \u2013&gt; \u201cAll device profiles\u201d -&gt; click <img loading=\"lazy\" decoding=\"async\" width=\"43\" height=\"38\" class=\"wp-image-5709287\" style=\"width: 43px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-127-1.png\" alt=\"\">on the profile you want to replace and select the created profile from the list.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"202\" height=\"397\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-128-1.png\" alt=\"\" class=\"wp-image-5709288\" style=\"width:214px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<ol start=\"8\" class=\"wp-block-list\">\n<li>Set the status to \u201cActive\u201d for the ballistic profile. To do this, click on the button <img loading=\"lazy\" decoding=\"async\" width=\"41\" height=\"43\" class=\"wp-image-5709289\" style=\"width: 41px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-129-1.png\" alt=\"\">next to the desired profile, or select it in the profile selection menu in the device.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"204\" height=\"397\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-130-1.png\" alt=\"\" class=\"wp-image-5709290\" style=\"width:229px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">9. Make sure that the <strong>activation<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"49\" height=\"51\" class=\"wp-image-5709291\" style=\"width: 49px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-131-1.png\" alt=\"\"> options is enabled in the devices External Ballistics <img loading=\"lazy\" decoding=\"async\" width=\"58\" height=\"48\" class=\"wp-image-5709292\" style=\"width: 58px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-132-1.png\" alt=\"\">menu.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"531\" height=\"424\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-133-1.png\" alt=\"\" class=\"wp-image-5709293\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-133-1.png 531w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-133-1-400x319.png 400w\" sizes=\"auto, (max-width: 531px) 100vw, 531px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Check the accuracy of your profile settings with a test shot at the shooting range.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Note: profiles for different types of ammunition must be zeroed separately.<\/p>\n\n\n\n<ol start=\"11\" class=\"wp-block-list\">\n<li>To activate the use of weather data in your geolocation during the shot, go to the \u201cDevices\u201d tab -&gt; Select your device -&gt; \u201cOutdoor\u201d.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"211\" height=\"415\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-134-1.png\" alt=\"\" class=\"wp-image-5709294\" style=\"width:222px;height:auto\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-134-1.png 211w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-134-1-203x400.png 203w\" sizes=\"auto, (max-width: 211px) 100vw, 211px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">In the <strong>External Ballistics <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"58\" height=\"48\" class=\"wp-image-5709292\" style=\"width: 58px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-132-1.png\" alt=\"\">section of the main menu, you can configure the following settings of the ballistic calculator:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Turn on\/off the ballistic calculator<\/li>\n\n\n\n<li>Select a ballistic profile<\/li>\n\n\n\n<li>Choose correction units<\/li>\n<\/ul>\n\n\n\n<ol start=\"12\" class=\"wp-block-list\">\n<li>Now when you measure distance with the rangefinder, a ballistic calculator widget will appear on the display with correction values in the selected units.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"522\" height=\"398\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-135-1.png\" alt=\"\" class=\"wp-image-5709295\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-135-1.png 522w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-135-1-400x305.png 400w\" sizes=\"auto, (max-width: 522px) 100vw, 522px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">This function is most useful when used with optical scopes. You can set the corrections by rotating the (windage\/elevation) turrets for aiming. Also, if your riflescope uses a Mil Dot reticle, you can shift it during aiming by the values of these corrections.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pulsar riflescopes (Thermion 2 Pro\/Duo\/XG, Thermion 2 LRF, Talion, Digex C50) already have a built-in manual ballistic calculator. Therefore, there will be enough to measure the distance with Symbion LRF and set it in the quick menu of the riflescope for the ballistic profile, having previously loaded it into the riflescope via SV Ballistics application.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"555\" height=\"403\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-136-1.png\" alt=\"\" class=\"wp-image-5709297\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-136-1.png 555w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-136-1-400x290.png 400w\" sizes=\"auto, (max-width: 555px) 100vw, 555px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">Stream Vision Ballistics Manual<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Android<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">iOS<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Discrete Digital Zoom<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The device allows you to quickly increase the basic magnification (please refer to the <strong>Magnification<\/strong> line in the<strong> Specifications <\/strong>table).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"774\" height=\"330\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-137-1.png\" alt=\"\" class=\"wp-image-5709299\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-137-1.png 774w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-137-1-400x171.png 400w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-137-1-768x327.png 768w\" sizes=\"auto, (max-width: 774px) 100vw, 774px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>To operate the discrete digital zoom, press successively the <strong>BACK <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"50\" class=\"wp-image-5709302\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-46-2.png\" alt=\"\">button.<\/li>\n\n\n\n<li>The digital zoom will not be saved after the device is restarted.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Wi-Fi Function<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The device has a function enabling wireless communication with external devices (smartphone or tablet) via Wi-Fi.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Turn on the wireless module in the main menu:<strong> Device Settings<\/strong> <img loading=\"lazy\" decoding=\"async\" width=\"81\" height=\"63\" class=\"wp-image-5709303\" style=\"width: 81px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-138-2.png\" alt=\"\"> Wi-Fi<img loading=\"lazy\" decoding=\"async\" width=\"37\" height=\"40\" class=\"wp-image-5709238\" style=\"width: 37px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-85-1.png\" alt=\"\">. Wi-Fi operation is shown in the status bar as follows:<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Status bar indication<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Connection status<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"46\" height=\"50\" class=\"wp-image-5709304\" style=\"width: 46px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-139-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Wi-Fi is off<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"77\" height=\"51\" class=\"wp-image-5709305\" style=\"width: 77px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-140-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Wi-Fi activated by the user,<br>Wi-Fi in the device is being activated<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"52\" class=\"wp-image-5709306\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-141-1.png\" alt=\"\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Wi-Fi is on, no connection with device<br>Wi-Fi is on, device connected<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Your device is detected by an external device as Symbion_[serial number].<\/li>\n\n\n\n<li>After entering the password on a mobile device (see <strong>Password Setup<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709239\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-86-1.png\" alt=\"\"> subsection of the <strong>Wi-Fi Settings<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"51\" height=\"40\" class=\"wp-image-5709307\" style=\"width: 51px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-142-1.png\" alt=\"\"> section for more information on setting a password) and connection is established, the icon<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"37\" class=\"wp-image-5709124\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-144.png\" alt=\"\"> in the status bar will change to<img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709239\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-86-1.png\" alt=\"\"> .<\/li>\n\n\n\n<li>The Wi-Fi function will turn off automatically if there is not enough battery power for Wi-F<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Installing the Device on a Tripod<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"435\" height=\"363\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-145-1.png\" alt=\"\" class=\"wp-image-5709308\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-145-1.png 435w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-145-1-400x334.png 400w\" sizes=\"auto, (max-width: 435px) 100vw, 435px\" \/><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\">\n<li>Attach the tripod adapter to the mounting socket <strong>(1)<\/strong>.<\/li>\n\n\n\n<li>Screw the adapter handle <strong>(2) <\/strong>clockwise until it is securely tightened.<\/li>\n\n\n\n<li>Mount the device with the adapter onto the tripod. The adapter is compatible with <strong>Arca-Swiss mounts<\/strong><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">USB Connection<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect one end of the USB cable to the USB Type-C connector of the device, the other one to the USB port on your computer using a USB Type-A adapter.<\/li>\n\n\n\n<li>Turn the device on (device that has been turned off cannot be detected by your computer).<\/li>\n\n\n\n<li>Your device will be detected by the computer automatically; no drivers need to be installed.<\/li>\n\n\n\n<li>Three connection modes will appear on the image:<strong> Device charging,<\/strong> <strong>File access (external memory)<\/strong> and <strong>Video stream<\/strong>.<\/li>\n\n\n\n<li>Select connection mode by rotating the controller ring<img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"48\" class=\"wp-image-5709187\" style=\"width: 45px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-42-1.png\" alt=\"\"> .<br>6, Confirm selection with a short press of the<strong> MENU <\/strong>button.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Device charging<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In this mode, when a computer is used as an external power supply, the icon <img loading=\"lazy\" decoding=\"async\" width=\"70\" height=\"35\" class=\"wp-image-5709151\" style=\"width: 70px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-14-1.png\" alt=\"\">appears in the tatus bar. The device will continue operating and all functions are available.<\/li>\n\n\n\n<li>The Battery pack installed in the device is not being charged!<\/li>\n\n\n\n<li>A battery recharge feasibility depends on your computer\u2019s USB port.<\/li>\n\n\n\n<li>When the USB is disconnected from the device connected as the <strong>Device charging <\/strong>mode, the device continues operating from the rechargeable batteries if they are sufficiently charged.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">File access<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In this mode the device is detected by the computer as a flash card.<\/li>\n\n\n\n<li>This mode is designed for work with the files saved in device\u2019s memory. The device\u2019s functions are not available in this mode; the device turns off automatically.<\/li>\n\n\n\n<li>If video recording was in progress when connection was made, recording stops and video is saved.<\/li>\n\n\n\n<li>If the device is in <strong>File access <\/strong>mode and is disconnected from USB, the device will remain on.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Video stream<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The device can be connected to PC or smartphone via USB Type-C cable.<br>The device is recognized as a web camera and accessed via any app that can work with web cameras. Signal from USB has better quality and latency and can be recorded or edited with software on the connected device.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During the video stream it is possible to record the observed picture. Activation of video recording is only available from the device itself by briefly pressing the <strong>REC<\/strong><img loading=\"lazy\" decoding=\"async\" width=\"53\" height=\"46\" class=\"wp-image-5709268\" style=\"width: 53px;\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-108-1.png\" alt=\"\"><strong> <\/strong>button.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>NOTE!<\/strong> Feature is supported only with iPhones that have USB Type-C port. To view the video stream, use any application (on desktop or mobile platforms) that supports the UVC video standard. Image transfer latency may occur in some applications. To reduce latency, disable the buffer in the application settings.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Software<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Stream Vision 2<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Install the Stream Vision 2 application to download files, update firmware, control the device by remote  control and broadcast images from your device to a smartphone or a tablet via WiFi. We recommend using the latest version \u2013 Stream Vision 2.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Stream Vision Ballistics<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Stream Vision Ballistics app is a full-featured mobile ballistic calculation tool for accurate longer-range shooting. You can pair the app with supporting Pulsar device or any daytime scope. We use proprietary algorithms to provide accurate, flexible, and reliable point-of-impact suggestions. To get them working, create a ballistic profile (or multiple) and enter the required data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Download<\/strong> from Google Play<br><strong>Download<\/strong> from App Store<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Stream Vision Ballistics Manual<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Android<\/strong><br><strong>iOS<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Firmware Update<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Download the free Stream Vision 2 App in Google Play or App Store.<\/li>\n\n\n\n<li>Connect your Pulsar device to your mobile device (smartphone or tablet).<\/li>\n\n\n\n<li>Launch Stream Vision 2 and go to section \u201cSettings\u201d.<\/li>\n\n\n\n<li>Select your Pulsar device and press \u201cCheck firmware update\u201d.<\/li>\n\n\n\n<li>Wait for the update to download and install. Pulsar device will reboot and will be ready to operate.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Important:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">if your Pulsar device is connected to a phone or mobile device, please turn on mobile data transfer (GPRS\/3G\/4G) to download update; if your Pulsar device is not connected to your phone or mobile device but is already listed in \u201cSettings\u201d &gt; \u201cMy devices\u201d section, you may use Wi-Fi to download update. Find answers to frequently asked questions about using Stream Vision 2 <strong>here.<\/strong> <strong>Is your firmware up to date?<\/strong> Click here to check the latest firmware for your device.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Maintenance<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Inspection<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">It is recommended to inspect your device before each use. Check the following:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The device should be free of any cracks or deformations.<\/li>\n\n\n\n<li>The lenses and protective glass should be free of cracks, grease, dirt or debris.<\/li>\n\n\n\n<li>The battery level of the device should be full. Electrical sockets should be free of salts, oxidation, or other debris.<\/li>\n\n\n\n<li>All controls should be responsive.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Maintenance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenance should be carried out at least twice a year and should include the following steps:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Wipe the exterior surfaces of metal and plastic parts with a cotton cloth. Do not use chemically active substances, solvents, etc. as these will damage the paint.<\/li>\n\n\n\n<li>Clean the electric terminals of the Battery Pack and device\u2019s battery slot using a grease-free organic solvent.<\/li>\n\n\n\n<li>Inspect the following optical components for cleanliness and damage:<\/li>\n\n\n\n<li>Eyepiece lenses<\/li>\n\n\n\n<li>Objective lenses<\/li>\n\n\n\n<li>Protective glass of the IR illuminator<\/li>\n\n\n\n<li>Protective glass of the laser rangefinder If necessary, remove dust and sand using a non-contact method whenever possible. Clean the exterior surfaces of the optics only with cleaning agents specifically designed for optical components.<\/li>\n\n\n\n<li>Avoid getting repellent on the housing of the device. This may damage the appearance of the housing coating.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Storage<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Always store the device in its carrying case in a dry, well-ventilated space.<\/li>\n\n\n\n<li>Remove the Battery Pack for long-term storage.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Troubleshooting<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For technical support please contact <strong>support@pulsar-vision.com<\/strong>. Answers to frequently asked questions about the devices can also be found in the <strong>FAQ<\/strong> section.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The device does not turn on<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>The batteries are completely discharged.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Charge the batteries.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Device malfunction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>In case of any malfunctions during operation, try resetting the device by long pressing the ON\/OFF button for 10 seconds.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The device does not operate on external power supply<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>USB cable is damaged.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Replace USB cable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>The external power supply is discharged.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Charge the external power supply.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The thermal image is blurry, with vertical stripes and uneven background<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Calibration is required.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Carry out calibration according to <strong>Calibration<\/strong> section.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Black screen after calibration<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>If the image does not clear after calibration, you need to recalibrate.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When the device is turned on, the calibration frequency is at first higher, then decreases (if the automatic calibration mode is enabled)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>After turning on the device, it takes some time for the microbolometer temperature to stabilize. This is ormal and is not a defect.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Colored lines appeared on display or image has disappeared<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>The device was exposed to static electricity during operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>After exposure to static electricity, the device may either reboot automatically, or require turning off and on again.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The image is too dark<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Brightness or contrast level is too low.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Adjust the brightness or contrast level in the<strong> Quick Menu.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Poor image quality \/ Detection range reduced<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Problems described may arise in adverse weather conditions (snow, rain, fog etc.).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Wrong settings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Adjust the device according to the Getting Started section. Check the outer surfaces of the lenses and the eyepieces and, where necessary, wipe away dust, condensation, frost, etc. In cold weather, you can use special anti-fogging coatings (e.g., the same as for corrective glasses).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Smartphone or tablet cannot be connected to the device<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Password in the device was changed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Delete network and connect again inserting the password saved in the device.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>There are too many Wi-Fi networks in the area where the device is located which may cause signal interference.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>To ensure stable Wi-Fi performance, move the device to an area with few or no Wi-Fi networks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br><strong>Switch <\/strong>the device\u2019s Wi-Fi band.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>The device has a 5 GHz network enabled, but the smartphone only supports 2.4 GHz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br><strong>Switch<\/strong> the device\u2019s Wi-Fi band to 2.4 GHz.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Wi-Fi signal is missing or interrupted<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Smartphone or tablet is out of range of a strong Wi-Fi signal. There are obstacles between the device and the smartphone or tablet (e.g.,  concrete walls).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Relocate smartphone or tablet into the Wi-Fi signal line of sight.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The thermal image of the object being observed is missing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>The presence of such pixels is associated with the manufacturing technology of displays and microbolometer. It is not a defect.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When using the device at below zero temperatures the image quality is worse than at positive temperatures<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>In warm climates, objects in the background of a thermal image heat up differently because of thermal conductivity, generating a high temperature contrast and a sharper thermal image. In cold climates, objects in the background of a thermal image will cool down to roughly the same temperature, which leads to a greatly reduced temperature contrast and a degraded image quality. This is normal for all thermal imaging devices.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rangefinder will not measure distance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>There is an object in front of the receiver or emitter lens preventing signal transmission.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Make sure that: the lenses are not blocked by your hand or fingers; the lenses are clean.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>The device is not being held steadily when measuring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Keep the device steady when measuring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Distance to the object exceeds 1500 m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Pick an object at a distance not longer than 1500 m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Low reflection ratio (for example, tree leaves).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Pick an object with higher reflection ratio (see point Additional <strong>Information<\/strong> in section<strong> Using the Laser Rangefinder<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Large measurement error<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Inclement weather conditions (rain, mist, snow).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Measurement distance is less than 10 m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Perform the measurement at a distance greater than 10 m.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">There is no thermal imaging or digital image<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Possible cause<\/strong><br>Lens cover closed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solution<\/strong><br>Open the covers of the thermal imaging and digital channels.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Legal Compliances and Disclaimers<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Attention!<\/strong> Symbion multispectral imaging binoculars require a license if exported outside your country.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Electromagnetic Compliance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This product complies with EU Standard EN 55032:2015, Class A.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Warning! <\/strong>Operation of this equipment in a residential environment could cause radio interference.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"460\" height=\"320\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-146-1.png\" alt=\"\" class=\"wp-image-5709311\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-146-1.png 460w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-146-1-400x278.png 400w\" sizes=\"auto, (max-width: 460px) 100vw, 460px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Caution<\/strong> \u2013 use of controls or adjustments or performance of procedures other than those specified herein  may result in hazardous radiation exposure. The manufacturer reserves the right at any time, without  mandatory prior notice to the Customer, to make changes to the package contents (subject to the applicable laws, if any), design and characteristics that do not impair the quality of the Product. Repair of the device is possible within 5 years.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"423\" height=\"123\" src=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-147-1.png\" alt=\"\" class=\"wp-image-5709312\" srcset=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-147-1.png 423w, https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/04\/Pulsar-Sybion-147-1-400x116.png 400w\" sizes=\"auto, (max-width: 423px) 100vw, 423px\" \/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Specification Model DXT50 SKU 77456 Microbolometer Type uncooled Resolution, pixels 1280\u00d71024 Pixel Pitch, \u00b5m 12 Sensor NETD, mK &lt; 40 System NETD, mK &lt; 20 Frame rate, Hz 50 Digital Sensor Type CMOS Resolution, pixels 3840\u00d72160 Optical Characteristics Thermal imaging channel: Lens 50 mm F\/1.0 Magnification, x 2 \u2013 16 Field of view angle (horizontal),&hellip;&nbsp;<a href=\"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/\" rel=\"bookmark\">Read More &raquo;<span class=\"screen-reader-text\">Pulsar Symbion Instruction Manual<\/span><\/a><\/p>\n","protected":false},"author":32,"featured_media":5710068,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","neve_meta_reading_time":"","footnotes":""},"categories":[763,8023,8051],"tags":[],"class_list":["post-5708980","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-instruction-manuals","category-nightvision-instruction-manuals","category-thermal-imaging-instruction-manuals"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pulsar Symbion Instruction Manual - Optics Trade Blog<\/title>\n<meta name=\"description\" content=\"The Symbion series by Pulsar represents a next-generation line of multispectral binoculars that combine thermal imaging and digital vision in a single device. Designed for hunters, professional users, and search and rescue teams, Symbion devices allow seamless switching between detection and detailed visual identification in any lighting conditions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pulsar Symbion Instruction Manual - Optics Trade Blog\" \/>\n<meta property=\"og:description\" content=\"The Symbion series by Pulsar represents a next-generation line of multispectral binoculars that combine thermal imaging and digital vision in a single device. Designed for hunters, professional users, and search and rescue teams, Symbion devices allow seamless switching between detection and detailed visual identification in any lighting conditions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/\" \/>\n<meta property=\"og:site_name\" content=\"Optics Trade Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OpticsTrade\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-29T07:30:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-29T09:52:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png\" \/>\n\t<meta property=\"og:image:width\" content=\"602\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Alja\u017e\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alja\u017e\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"81 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/\"},\"author\":{\"name\":\"Alja\u017e\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#\\\/schema\\\/person\\\/10caafddbfe517dcbfaa417ac8f7c74d\"},\"headline\":\"Pulsar Symbion Instruction Manual\",\"datePublished\":\"2026-04-29T07:30:52+00:00\",\"dateModified\":\"2026-05-29T09:52:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/\"},\"wordCount\":7742,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Posnetek-zaslona-2026-05-29-114859.png\",\"articleSection\":[\"Instruction Manuals\",\"Night Vision - Instruction Manuals\",\"Thermal Imaging - Instruction Manuals\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/\",\"url\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/\",\"name\":\"Pulsar Symbion Instruction Manual - Optics Trade Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Posnetek-zaslona-2026-05-29-114859.png\",\"datePublished\":\"2026-04-29T07:30:52+00:00\",\"dateModified\":\"2026-05-29T09:52:43+00:00\",\"description\":\"The Symbion series by Pulsar represents a next-generation line of multispectral binoculars that combine thermal imaging and digital vision in a single device. Designed for hunters, professional users, and search and rescue teams, Symbion devices allow seamless switching between detection and detailed visual identification in any lighting conditions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Posnetek-zaslona-2026-05-29-114859.png\",\"contentUrl\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Posnetek-zaslona-2026-05-29-114859.png\",\"width\":602,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/pulsar-symbion-instruction-manual\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Night Vision\",\"item\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/category\\\/nv-optics\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Night Vision - Instruction Manuals\",\"item\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/category\\\/nv-optics\\\/nightvision-instruction-manuals\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Pulsar Symbion Instruction Manual\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/\",\"name\":\"Optics Trade Blog\",\"description\":\"Articles about binoculars, riflescopes, spotting scopes and other sport optics\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#organization\",\"name\":\"Optics Trade\",\"url\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/OpticsTradeBlog_logo-27.png\",\"contentUrl\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/OpticsTradeBlog_logo-27.png\",\"width\":2026,\"height\":241,\"caption\":\"Optics Trade\"},\"image\":{\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/OpticsTrade\\\/\",\"https:\\\/\\\/www.instagram.com\\\/opticstrade.hunting\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/optics-trade\",\"https:\\\/\\\/www.pinterest.com\\\/opticstrade\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/OpticsTradeEU\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/#\\\/schema\\\/person\\\/10caafddbfe517dcbfaa417ac8f7c74d\",\"name\":\"Alja\u017e\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ea2807f3574302b1938ea75fe8518f3f82149ae7b751555b37bb8c212ec08d75?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ea2807f3574302b1938ea75fe8518f3f82149ae7b751555b37bb8c212ec08d75?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ea2807f3574302b1938ea75fe8518f3f82149ae7b751555b37bb8c212ec08d75?s=96&d=mm&r=g\",\"caption\":\"Alja\u017e\"},\"url\":\"https:\\\/\\\/www.optics-trade.eu\\\/blog\\\/author\\\/aljazstimec\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pulsar Symbion Instruction Manual - Optics Trade Blog","description":"The Symbion series by Pulsar represents a next-generation line of multispectral binoculars that combine thermal imaging and digital vision in a single device. Designed for hunters, professional users, and search and rescue teams, Symbion devices allow seamless switching between detection and detailed visual identification in any lighting conditions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/","og_locale":"en_US","og_type":"article","og_title":"Pulsar Symbion Instruction Manual - Optics Trade Blog","og_description":"The Symbion series by Pulsar represents a next-generation line of multispectral binoculars that combine thermal imaging and digital vision in a single device. Designed for hunters, professional users, and search and rescue teams, Symbion devices allow seamless switching between detection and detailed visual identification in any lighting conditions.","og_url":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/","og_site_name":"Optics Trade Blog","article_publisher":"https:\/\/www.facebook.com\/OpticsTrade\/","article_published_time":"2026-04-29T07:30:52+00:00","article_modified_time":"2026-05-29T09:52:43+00:00","og_image":[{"width":602,"height":400,"url":"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png","type":"image\/png"}],"author":"Alja\u017e","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alja\u017e","Est. reading time":"81 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#article","isPartOf":{"@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/"},"author":{"name":"Alja\u017e","@id":"https:\/\/www.optics-trade.eu\/blog\/#\/schema\/person\/10caafddbfe517dcbfaa417ac8f7c74d"},"headline":"Pulsar Symbion Instruction Manual","datePublished":"2026-04-29T07:30:52+00:00","dateModified":"2026-05-29T09:52:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/"},"wordCount":7742,"commentCount":0,"publisher":{"@id":"https:\/\/www.optics-trade.eu\/blog\/#organization"},"image":{"@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#primaryimage"},"thumbnailUrl":"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png","articleSection":["Instruction Manuals","Night Vision - Instruction Manuals","Thermal Imaging - Instruction Manuals"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/","url":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/","name":"Pulsar Symbion Instruction Manual - Optics Trade Blog","isPartOf":{"@id":"https:\/\/www.optics-trade.eu\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#primaryimage"},"image":{"@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#primaryimage"},"thumbnailUrl":"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png","datePublished":"2026-04-29T07:30:52+00:00","dateModified":"2026-05-29T09:52:43+00:00","description":"The Symbion series by Pulsar represents a next-generation line of multispectral binoculars that combine thermal imaging and digital vision in a single device. Designed for hunters, professional users, and search and rescue teams, Symbion devices allow seamless switching between detection and detailed visual identification in any lighting conditions.","breadcrumb":{"@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#primaryimage","url":"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png","contentUrl":"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2026\/05\/Posnetek-zaslona-2026-05-29-114859.png","width":602,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/www.optics-trade.eu\/blog\/pulsar-symbion-instruction-manual\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.optics-trade.eu\/blog\/"},{"@type":"ListItem","position":2,"name":"Night Vision","item":"https:\/\/www.optics-trade.eu\/blog\/category\/nv-optics\/"},{"@type":"ListItem","position":3,"name":"Night Vision - Instruction Manuals","item":"https:\/\/www.optics-trade.eu\/blog\/category\/nv-optics\/nightvision-instruction-manuals\/"},{"@type":"ListItem","position":4,"name":"Pulsar Symbion Instruction Manual"}]},{"@type":"WebSite","@id":"https:\/\/www.optics-trade.eu\/blog\/#website","url":"https:\/\/www.optics-trade.eu\/blog\/","name":"Optics Trade Blog","description":"Articles about binoculars, riflescopes, spotting scopes and other sport optics","publisher":{"@id":"https:\/\/www.optics-trade.eu\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.optics-trade.eu\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.optics-trade.eu\/blog\/#organization","name":"Optics Trade","url":"https:\/\/www.optics-trade.eu\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.optics-trade.eu\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2024\/02\/OpticsTradeBlog_logo-27.png","contentUrl":"https:\/\/www.optics-trade.eu\/blog\/wp-content\/uploads\/2024\/02\/OpticsTradeBlog_logo-27.png","width":2026,"height":241,"caption":"Optics Trade"},"image":{"@id":"https:\/\/www.optics-trade.eu\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OpticsTrade\/","https:\/\/www.instagram.com\/opticstrade.hunting\/","https:\/\/www.linkedin.com\/company\/optics-trade","https:\/\/www.pinterest.com\/opticstrade","https:\/\/www.youtube.com\/user\/OpticsTradeEU"]},{"@type":"Person","@id":"https:\/\/www.optics-trade.eu\/blog\/#\/schema\/person\/10caafddbfe517dcbfaa417ac8f7c74d","name":"Alja\u017e","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ea2807f3574302b1938ea75fe8518f3f82149ae7b751555b37bb8c212ec08d75?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ea2807f3574302b1938ea75fe8518f3f82149ae7b751555b37bb8c212ec08d75?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ea2807f3574302b1938ea75fe8518f3f82149ae7b751555b37bb8c212ec08d75?s=96&d=mm&r=g","caption":"Alja\u017e"},"url":"https:\/\/www.optics-trade.eu\/blog\/author\/aljazstimec\/"}]}},"lang":"en","translations":{"en":5708980},"pll_sync_post":{},"_links":{"self":[{"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/posts\/5708980","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/comments?post=5708980"}],"version-history":[{"count":0,"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/posts\/5708980\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/media\/5710068"}],"wp:attachment":[{"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/media?parent=5708980"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/categories?post=5708980"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.optics-trade.eu\/blog\/wp-json\/wp\/v2\/tags?post=5708980"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}